background image

 

 

 

 

 

 

 

 

 

1.2. End limits reset (factory default)

This procedure will erase all limits stored in the volatile motor memory. It will not clear the Network ID and Group

assignments. Completing an End limits reset will prevent a PowerView® remote or App from operating a window covering

until it is reprogrammed.

1.1.1

Power up

 the motor by connecting the power cable to

the battery wand or power supply.

1.1.2

Immediately Check

 the motor button LED sequence

after start up.

1.1.3

The LED sequence should read:

Freehanging Plissé

 type

Freehanging Duette®

 type

Tensioned Plissé

 type

Tensioned Duette®

 type

MANUAL

Page 3 of 20

version: 1.1

Summary of Contents for PowerView EOS Duette

Page 1: ...perate the blind within the prescribed environmental situation the motor may only be used in combination with the recommended and suitable power source originally supplied with the blind A remote control is considered NOT to be a children s toy window decoration motors should be replaced when the rated cycle limitation is reached Never drop the motor Never drill into the motor Do not immerse into ...

Page 2: ...d for freehanging blinds Freehanging Plissé Freehanging Duette The motor can be programmed for tensioned blinds Tensioned Plissé Tensioned Duette By reading out the LED sequence after power up the motor type can be seen Plissé Duette IMPORTANT The motor type default set to Venetian blind has to be changed to Plissé or Duette type Use the PowerView Programmer software tool to change IMPORTANT It is...

Page 3: ...ent a PowerView remote or App from operating a window covering until it is reprogrammed 1 1 1 Power up the motor by connecting the power cable to the battery wand or power supply 1 1 2 Immediately Check the motor button LED sequence after start up 1 1 3 The LED sequence should read Freehanging Plissé type Freehanging Duette type Tensioned Plissé type Tensioned Duette type MANUAL Page 3 of 20 versi...

Page 4: ...the motor to confirm no limits are set 1 2 1 Remove power from the motor by disconnecting the power cable from the battery wand or power supply and wait for 20 seconds 1 2 2 Press and hold the manual control button on the motor 1 2 3 Reconnect power to the motor while press and hold the manual control button The motor LED turns red green MANUAL Page 4 of 20 version 1 1 ...

Page 5: ... until it is reprogrammed 1 2 4 Press and hold the manual control button until the motor jogs 1x 1 2 5 Release the manual control button The end limits have been cleared 1 3 1 Press and hold the manual control button on the motor for 12 seconds The blind will jog 1x at 6 seconds and a second time at 12 seconds 1 3 2 Release the manual control button after the second jog The Network ID and Group as...

Page 6: ...The instructions below assign a blind to group 1 2 1 Locate the manual control button on your blind 2 2 Press and hold the stop button for 6 seconds Keep pressing until the remote lights start blinking 2 3 Press the group1 button IMPORTANT Watch out to perform steps 2 4 and 2 5 within 3 seconds MANUAL Page 6 of 20 version 1 1 ...

Page 7: ...utton The blind will jog 1x 2 6 Release the manual control button 2 7 Press and hold the stop button for 6 seconds Keep pressing until the remote lights stop blinking The remote will exit programming mode automatically after 20 seconds MANUAL Page 7 of 20 version 1 1 ...

Page 8: ...d the motor direction has to be checked and reversed if needed If the top or bottom limit is already set and the motor direction has to be reversed perform a reset before continuing IMPORTANT Watch out to perform steps 3 1 1 and 3 1 2 within 3 seconds 3 1 1 Press and hold the manual control button 3 1 2 Press the open button The blind will jog 1x Make sure group1 on the remote is selected MANUAL P...

Page 9: ...e motor is in program mode 3 2 1 Press the arrow down button to check motor direction 3 2 2 A If the blind moves upwards Press the stop button Motor direction NOT OK 3 2 2 B If the blind moves downwards Press the stop button and continue with step 4 1 4 Motor direction OK MANUAL Page 9 of 20 version 1 1 ...

Page 10: ...limit top 3 2 3 Press and hold the manual control button for 1 second to reverse motor direction The blind will jog 1x to acknowledge the direction is reversed 3 2 4 Continue with step 4 1 4 4 1 1 Press and hold the manual control button 4 1 2 Press the open button The blind will jog 1x Make sure group1 on the remote is selected MANUAL Page 10 of 20 version 1 1 ...

Page 11: ...he open stop and close buttons to move the blind about 20cm below the headrail 4 1 5 Use the open button to let the blind hit the headrail The motor will stop moving The motor needs to hit the headrail 4 1 6 Move the blind to the desired top position with the open close and stop buttons MANUAL Page 11 of 20 version 1 1 ...

Page 12: ... lights start blinking IMPORTANT Watch out to perform steps 4 1 6 and 4 1 7 within 3 seconds 4 1 8 Press and hold the manual control button 4 1 9 Press the open button The blind will jog 1x to acknowledge the limit is set 4 1 10 Release the manual control button The motor LED turns off MANUAL Page 12 of 20 version 1 1 ...

Page 13: ...p pressing until the remote lights stop blinking The remote will exit programming mode automatically after 20 seconds 4 1 12 The top limit is set Note To re position the top limit of the blind repeat step 4 1 Open limit top MANUAL Page 13 of 20 version 1 1 ...

Page 14: ...n The blind will jog 1x Make sure group1 on the remote is selected 4 2 3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode 4 2 4 Use the open stop and close buttons to move the blind to the desired bottom position MANUAL Page 14 of 20 version 1 1 ...

Page 15: ... lights start blinking IMPORTANT Watch out to perform steps 4 2 6 and 4 2 7 within 3 seconds 4 2 6 Press and hold the manual control button 4 2 7 Press the close button The blind will jog 1x to acknowledge the limit is set 4 2 8 Release the manual control button The motor LED turns off MANUAL Page 15 of 20 version 1 1 ...

Page 16: ...ew of all possible combinations 4 2 9 Press and hold the stop button for 6 seconds Keep pressing until the remote lights stop blinking The remote will exit programming mode automatically after 20 seconds 4 2 10 The bottom limit is set Note To re position the bottom limit of the blind repeat step 4 2 Close limit bottom MANUAL Page 16 of 20 version 1 1 ...

Page 17: ... Tensioned Plissé Blind type Tensioned Duette After Reset End limits reset factory default see chapter 1 2 Network reset on manual control button release see chapter 1 3 Blind type Freehanging Plissé Network reset on manual control button release see chapter 1 3 Blind type Freehanging Duette MANUAL Page 17 of 20 version 1 1 ...

Page 18: ...n Low battery indication 11 0V The blind will run in slow mode and can only be send upwards Ultra low battery indication 8 5V The blind will not run anymore Change the batteries Others The maximum motor current has been reached E g The blind is stuck at an obstacle Continuous Steady red LED The motor is in program mode during limit setting Jog sequences Explanation MANUAL Page 18 of 20 version 1 1...

Page 19: ...ons applicable at the time of sale in accordance with its standard warranty terms Testing and other quality control techniques are used to the extent Hunter Douglas deems necessary to support this warranty Except where mandated by applicable law testing of all parameters of each component is not necessarily performed Hunter Douglas assumes no liability for applications assistance or the design of ...

Page 20: ...tered documentation Information of third parties may be subject to additional restrictions Resale of Hunter Douglas components or services with statements different from or beyond the parameters stated by Hunter Douglas for that component or service voids all express and any implied warranties for the associated Hunter Douglas component or service and is an unfair and deceptive business practice H...