General Maintenance

 

 

Changing Remote Batteries: 

-

 Batteries used in Handsets will weaken over time and should 

be  replaced  every  6  months.  Batteries  removed  from  the  handset  should  be  disposed  of 

properly and kept out of reach of children.

 

 

* Before maintenance ensure fan is switched off at the isolation switch or circuit breaker *

 

 

Cleaning the Motor Housings: 

-

 Motor housings should be cleaned every 3 to 4 months to 

avoid  build  up  of  dust.  Use  a  soft,  damp  cloth  to  remove  dust.  Use  only  water  and  mild 

detergent. Spray cleaners may damage coatings.

 

 

Cleaning the Blades: 

-

 Use a soft damp cloth to remove dirt from blades. Always dry blades  

after cleaning. Use only water and mild detergent. Spray cleaners may damage coatings.

 

 

Always use soft cloths to clean blades and motor housings to avoid scratching painted and 

plated finishes. Ideally your fan should be cleaned every 3 to 4 months. 

 

 

If removing blades for cleaning then do so for each fan separately, do not mix blades from 

different fans as this can upset the balance of the fan. Put blades back in the position they 

came from.

 

 

Normal Wear and Tear: 

-

 Please note that a ceiling fan travels an enormous distance in the 

course of its normal operation.  Air is abrasive and suspended dust, high humidity and other 

contamination will cause wear and tear of surfaces. 

 

 

The  use  of  fans  under  roofed  decks  and  pergolas  next  to  swimming  pools  and  in  coastal 

areas  will  require  increased  maintenance  due  to  the  presence  of  chlorides  (either  as     

common air borne salt spray or from compounds in pool chemicals)

 

  

Some colour discoloration on ABS polymer body and blade will occur over time.

 

 

1.

 

Do  not 

attempt to operate the fan or light (if fitted) with any wall control that is not approved by 

Hunter  Pacific  for  use  with  its  fans.  DO  NOT  use  solid  state  controllers.  The  use  of  unapproved      

controllers may void your warranty.

 

 

2.

 

Do not 

mix blade sets from one fan to another as this may upset the balance of the fan. If only 

one blade is damaged you are still required to replace with a new set.

 

Installation & User 

 

Manual

 

Summary of Contents for AQUA DC AIP2661

Page 1: ...OUR CUSTOMER S WARRANTY PLEASE READ PAGE 2 OF THIS BOOKLET PRIOR TO THE INSTALLATION OF THIS PRODUCT Installation User Manual After installation electricians must tick off all items on the quick checklist and fill out their details towards the back of this Installation and User Manual Isolation switch and wall plate required To suit the location and décor these parts must be supplied by the instal...

Page 2: ...lified persons To electricians and installers The Australian Competition and Consumer Law 2010 mandates consumer protection against defects or poor workmanship in provision of services such as installing a ceiling fan To protect yourself and the consumer these instructions must be followed Failure to do so may result in the consumer making a claim against you for consequential loss or damage 7 An ...

Page 3: ...es 7 0 kgs AIPL2667 AQUA 52 V2 CEILING FAN 18W CCT LED White Motor with White Polymer Blades 7 0 kgs AIPL2668 AQUA 52 V2 CEILING FAN 18W CCT LED Matt Black Motor with Matt Black Polymer Blades 7 0 kgs AIPL2669 AQUA 52 V2 CEILING FAN 18W CCT LED Matt Black with Koa Polymer Blades 7 0 kgs AIPL2670 AQUA 70 V2 CEILING FAN 18W CCT LED White Motor with White Polymer Blades 7 6 kgs AIPL2671 AQUA 70 V2 CE...

Page 4: ...aged you are still required to replace with a new set Fan Off Pressing the Fan Off button turns the fan off Fan Speed Button Forward Reverse Button Fan will spin in forward summer or reverse winter mode Pressing or to choose desired speed Pressing or to choose desired dimming Light On Off Turns the light on the fan on and off Fan Light Timber Off Button Light Dimming Button Pressing the button to ...

Page 5: ...r 5 seconds until the fan beeps once The DC Wall Controller will then be linked to the fan Either two remote handsets or one remote handset combined with one DC Wall Controller can be paired per fan and can control a maximum of two ceiling fans Please note maximum two ceiling fans using one DC wall controller Both fans must have their own receiver and the wall controller must be installed in the s...

Page 6: ... and the light will turn on the setting is now completed When POL is ON the light will turn on when power is applied to the receiver via an external switch or after a power failure POL OFF Turn on the wall switch isolation switch and turn the light off using remote handset Slowly press the Timer button 1H 4H 2H 1H 4H 2H The receiver will beep once and the light will turn off the setting is now com...

Page 7: ...cific for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 2 1m AU NZ 1 Fig 1 Fig 2 2 2 4 3 5 3 1 7 6 5 4 9 8 Fan no light loom Fan with LED light loom WARNING ALL SCREWS R...

Page 8: ...be used ONLY 1 Do not attempt to operate the fan or light if fitted with any wall control that is not approved by Hunter Pacific for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with ...

Page 9: ...ot attempt to operate the fan or light if fitted with any wall control that is not approved by Hunter Pacific for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 1 2 Fig 4...

Page 10: ...ed with any wall control that is not approved by Hunter Pacific for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set Fig 5 1 2 1 2 ...

Page 11: ...if fitted with any wall control that is not approved by Hunter Pacific for use with its fans DO NOT use solid state controllers The use of unapproved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set 1 1 2 1 2 2 ...

Page 12: ...oved controllers may void your warranty 2 Do not mix blade sets from one fan to another as this may upset the balance of the fan If only one blade is damaged you are still required to replace with a new set Installation User Manual Installation Instructions Replacing LED Light Fig 17 Fig 18 WARNING DO NOT REMOVE LED PLASTIC COVER LED REPLACMENT MUST BE INSTALLED BY LICENSED ELECTRICIANS 3 2 1 ...

Page 13: ...ng bracket is secure If ceiling canopy moves then the bracket or ceiling is moving and screws loose not into structure or of counter sunk type Troubleshooting Tips for Installers Light Light will not turn on Make sure lamp has not blown Check all light wires in the termi nal block in the canopy cover and the wall switch have been connected correctly Light flickers or flashes Re check wiring Flicke...

Page 14: ...o for each fan separately do not mix blades from different fans as this can upset the balance of the fan Put blades back in the position they came from Normal Wear and Tear Please note that a ceiling fan travels an enormous distance in the course of its normal operation Air is abrasive and suspended dust high humidity and other contamination will cause wear and tear of surfaces The use of fans und...

Page 15: ...ill spin in REVERSE Winter when viewed from underneath will be clockwise FORWARD Summer Mode Ceiling fans are an environmentally smart choice to assist with cooling and warming your home In FORWARD Summer mode your ceiling fan will spin to push air down the centre of the fan producing a cooling breeze The direction the fan will spin in FORWARD Summer when viewed from underneath will be anti clockw...

Page 16: ...eel structure or timber framing If additional bracing is added it must be firmly secured to the rafters and not left floating on the ceiling Special mounts such as T hooks are available for certain types of installation 5 Counter sunk screws are not to be used to attach bracket to ceiling 6 Fan blades are at least 2 1m 7 feet above floor level 7 Check the fan is operating correctly on all speeds 8...

Page 17: ...e for warranty claims CUSTOMER DETAILS Customer Name Installation Site Address INSTALLING ELECTRICIAN DETAILS Electrical company and Electrician Name License No Telephone Mobile Install Date Installation User Manual 1 Do not attempt to operate the fan or light if fitted with any wall control that is not approved by Hunter Pacific for use with its fans DO NOT use solid state controllers The use of ...

Page 18: ...18 Attach receipt here Attach electricians invoice here ...

Page 19: ...tioning properly as a result of faulty installation or lack of maintenance then Hunter Pacific International Pty Ltd or its service agent reserve the right to charge a service fee to rectify the reported problem Damage caused by incorrect installation force majeure electrical surges lightning power grid fluctuations water or alternative power supply sources such as solar inverters etc will not be ...

Page 20: ...Procedure For online warranty bookings visit www hunterpacific com au 24hours 7 days For technical advice call 1300 360 280 Monday to Thursday from 9am to 5pm EST Friday from 9am to 4pm EST Warranty only available within Australia V2 ...

Reviews: