IMPORTANT INFORMATION 

ELECTRICIANS MUST READ  PRIOR TO INSTALLATION 

 

1.  Distributor  and  installer  details  and  purchase  receipts  are  essential  for  on-site  warranty  claims 

and must be presented to repair personnel, make sure you record your details in the Fan Owner 
Warranty and Operations Manual. 

 
2.   Fans and fixed wiring products must only be installed by persons who are appropriately licensed 

by the applicable State regulatory body. Therefore, to protect our repair personnel, on-site  

 

warranty claims will not be accepted if products have been installed by unlicensed persons.   

 
3.

      

Damage  caused  by  incorrect  installation,  force-majeure,  electrical  surges,  lightning,  power  grid 

fluctuations,  water or by connection to alternative power supply sources (such as solar inverters, 
etc.) is not eligible for warranty repair. 

 
4.

      

Blades must be replaced only as a complete set. Blades are supplied only as a pre-balanced set 

and the replacement of individual blades may void the warranty by causing mechanical  

 

damage to the motor, excessive noise or premature wear. 

 
5.

      

When products are installed in a location requiring special access equipment (such as  

 

scaffolding  or  scissor  lifts,  etc)  the  cost  of  providing,  installing  and  operating  special  access 
equipment must be borne by the site owner.  

  

 

For safety, and to protect your customers warranty, the following must be taken into  
account when installing and operating the product(s): 

 
 

IF THERE ARE ANY PROBLEMS WITH THE PRODUCT AT TIME OF 

INSTALLATION THE INSTALLER MUST CONTACT THE WARRANTY 

HOT LINE NUMBER 

1300 360 280

BEFORE LEAVING THE JOB 

SITE.  PLEASE DO NOT REMOVE THE FAN FROM THE CEILING  

ONCE INSTALLED UNLESS INSTRUCTED TO DO SO. 

 
 

 

 
 

Electrician 

Installation Manual

 

Majestic Everglade Ceiling Fan 

(a)

    

DO NOT USE SOLID-STATE WALL CONTROLLERS. Neither leading nor lagging edge 

controllers will give satisfactory performance. Wall controls must only be types approved 
for use by Hunter Pacific International.   

(b)

   

The fan, light and bracket must be earthed. 

(c)

    

Fan and light must be run from the same phase and preferably the same final circuit. 

(d)

    

Mounting bracket must be firmly screwed to a solid structure such as a concrete ceiling, 

steel structure or timber framing. If additional bracing is added it must be firmly secured to 
the rafters and not left  floating on the ceiling. Special mounts, such as T-hooks, are  

 

available for certain types of installation. 

(e)

    

After installation, fan blades must be at least 2.1 m (7 feet) above floor level. 

(f)

     

The use of these products by children and the infirm must be under supervision. 

Summary of Contents for Majestic Everglade

Page 1: ...he Fan Owner Warranty Operations Manual National Warranty Line 1300 360 280 Monday to Friday from 9am to 5pm EST Only available within Australia Hunter Pacific International Pty Ltd Building 8 256 New Line Road Dural NSW 2158 Australia ABN 18 063 521 666 NOTE Blades may differ from the one shown in the above image as Everglade motors have a selection of suitable blade choices ELECTRICIANS TO PROTE...

Page 2: ...the cost of providing installing and operating special access equipment must be borne by the site owner For safety and to protect your customers warranty the following must be taken into account when installing and operating the product s IF THERE ARE ANY PROBLEMS WITH THE PRODUCT AT TIME OF INSTALLATION THE INSTALLER MUST CONTACT THE WARRANTY HOT LINE NUMBER 1300 360 280 BEFORE LEAVING THE JOB SI...

Page 3: ... Pin 1 Down Rod Cotter Key 1 these parts come preassembled Pull cord Assembly Kit comes preassembled 1x pull cord assembly 1x start up capacitor 1x speed capacitor 1x pull chain 3x screws and 2x lights wires Blade Holders 5 Motor Housing 1 HPI Wall Controller 1 Blade Screws 20 Canopy Cover 1 Wall Speed Capacitor 1 Blade Holders Screws 10 Motor Housing Cap 1 Hanger Bracket Hex Head Screw Ball Joint...

Page 4: ... COLOUR 878 Majestic Broadleaf Brown SIZE 137cm 54 877 137cm 54 Majestic Broadleaf White 879 137cm 54 Majestic Palm Natural 880 137cm 54 Majestic Bamboo White 881 137cm 54 Majestic Bamboo Brown Electrician Installation Manual Majestic Everglade Ceiling Fan 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved by Hunter Pacific for use with its fans DO...

Page 5: ...for wiring b Secure the hanger bracket onto the timber nogging using the two hex head screws provided The timber nogging should be supplied by the installing electrician and must be supported between the two ceiling joists as shown in the diagram above STEP 1 Fig 1 ONLY PERFORM THIS STEP IF FAN WIRES HAVE NOT BEEN FED THROUGH DOWN ROD a Loosen the ball joint screw and remove the ball joint pin to ...

Page 6: ...th Wire Blue Neutral Wire Brown Active Wire Black White for Light Brown for Fan Fan Motor Light Active Brown Light Fitting Wiring Instructions with and without accessory light Light Controlled from Wall Controller and Fan Controlled by Pull Cord Fig 5 Switch Wire Brown Blue Black White Earth Wires 1 Do not attempt to operate the fan or optional light kit with any wall control that is not approved ...

Page 7: ...TEP 6 Fig 7 a Attach blades on to the blade holders as shown in figure 7 Fig 7 Fig 8 STEP 8 Fig 9 a Unscrew the pull cord screws to separate the pull cord assembly kit from the motor housing If you are attaching a light kit go to page 8 b Make sure the two ends of the nine pin plug are connected together and the colours on the plugs are corresponding c Use pull cord screws to re secure the pull co...

Page 8: ... by tightening the thread clockwise as shown in figure 11 d Connect light wires to terminal block in lower part of the light kit e Reattach lower part of the light kit to the top cover of the light kit using the three screws removed from step 2a Plug Pull Cord Assembly Kt Light Kit Screw Light Wires Terminal Block Thread Top Cover of Light Kit Lower Part of Light Kit Fig 11 1 Do not attempt to ope...

Page 9: ...control Make sure globe has not blown and it is properly fitted between the metal prongs Check all light wires in the light kit the terminal block in the canopy cover and the wall switch has been connected together correctly Check dip switch settings in remote hand piece and remote receiver are corresponding Light wires appear to be missing or too short Wires may be stuck in the motor housing Care...

Page 10: ...e the rod to the fan and the ball joint NOTE If the extension rod needs to be shortened cut the rod to the required length and drill the appropriate hole size to fit the ball joint pin The cut end of the rod should be used on the ball joint end only When installing a 1 8m extension rod the wiring will need to be extended and joined This should be done using crimp style connectors Cotter Pin Fig 13...

Page 11: ...h is pushed into its Summer or Winter position Fan is not corresponding to the remote control Check for flat battery Make sure the dipswitch settings in the hand piece and the remote receiver for the same fan are corresponding Fan is wobbling Check the ball joint slot is locked into the hanger bracket groove Make sure blades are a matching set the letters on matching sets of blades should be ident...

Page 12: ...ler 7 If light is installed Check light switch is functioning properly 8 If remote control is installed Check the fan and light if installed is responding to the remote control correctly 9 If remote control is installed Check where possible a separate isolation switch has been installed for the fan 10 Check electrician s details have been recorded onto the back page of the Owner s Operations and W...