background image

23 

JINTDBW09 Rev B 05/03/15 

 

Body Assembly Spares 

 
 
 
 
 
 
 
 
 
 

 

 
 

 

 
 
 
 
 
 
 
 
 
 

 

 

REAR GRATE 
SUPPORT 
HDW09012 

GRATE BARS 
UPPER: P112032 
LOWER: P112033 

OPERATING TOOL 
HFR07040 

FUEL RETAINER 
HCW09ARRT025 

HINGE PIN 
FRRE08-1.75 

HINGE 
HH06050 

BRICK 
LEFT: HCW09051A 
RIGHT: HCW09051B 

SLIDER KNOB 
HCE05040M 

BAFFLE 
HCW09ARRT011 

CAM BAR 
HCW09ARRT020 

ASHPAN 
HDW09ARRT007 

BAFFLE SUPPORT 
HCW09ARRT013 

CATCH BAR 
HDW09ARRT008 

Summary of Contents for Telford Inset 20DB CVWSTI08DBFM

Page 1: ...JINTDBW09 Rev B 05 03 15 Telford Inset 20DB Multifuel Boiler Stove Model CVWSTI08DBFM CVWTI08DBFM Instructions for Installation Operating Maintenance Servicing...

Page 2: ...omponents and the use of un authorised fuels Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles Thermostat and the surface finish of the appliance The Warranty wil...

Page 3: ...mission at 13 O2 0 33 Mean Flue Gas Temperature 385 C EFFICIENCY 69 9 Flue Gas Mass Flow 14 1g s Maximum operating water temperature in C 100 C Maximum operating pressure in bar 1 2 Bar Minimum cleara...

Page 4: ...ds must not be installed in the same space or room as this can cause the appliance to emit fumes into the room Do not obstruct the ventilation required for the safe use of this appliance COMPETENT PER...

Page 5: ...emit fumes Occasional fumes from de ashing and refueling may occur Persistent fume emission must not be tolerated This appliance should not be operated with the door open If fume emission does persis...

Page 6: ...r by lifting upwards of its supports and remove from firebox 3 Remove the fuel retainer support front plate by lifting the fuel retainer support clear from its locating slots Then remove 4 Remove the...

Page 7: ...ear grate bar support by lifting the grate bar support clear of the locating slots and remove 9 Remove the baffle by sliding it forward until it reaches its stop Then lift and slide forward until clea...

Page 8: ...onry and flue block chimneys must meet the requirements of Building Regulations Document J Any connecting flue pipe systems must also meet these regulations Please check the suitability of the firepla...

Page 9: ...are and attention to meet the requirements of the Health Safety code of practice and any other legislation that may have been introduced since the publication of these instructions COMPETENT PERSONS S...

Page 10: ...uld extend to at least 300mm in front of the stove and 150mm at the sides The constructional hearth should be made of solid non combustible material and can include any solid non combustible floor The...

Page 11: ...m Installing the Stove 1 Check positions of pipe connections 2 Make suitable access holes so you can access the tappings and infill with vermiculite concrete 3 Apply fire cement around the rope seal T...

Page 12: ...ed that a flue forming pipe short length of flue pipe is used and the void between the flue forming pipe and the chimney is filled with vermiculite concrete A suitable access hole will need to be made...

Page 13: ...o the cylinder The cylinder and heat leak radiator must be sited higher than the stove Semi pumped systems should be used on heating and hot water systems with gravity circulation to the hot water cyl...

Page 14: ...C Circulating Pump Low Limit Thermostat 45 C Time Switch Drain Cock Injector Tee Four Tapping System Two Tapping System Wiring Diagram for general guidance only All electrical work must be carried out...

Page 15: ...owly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the door move the Baffle to the re fuelling position see instructions on page 1...

Page 16: ...ws open AEROSOLS Do not use an aerosol spray on or near the stove when it is alight AIR CONTROLS This stove has been designed to burn cleaner and more efficiently than a conventional stove If used cor...

Page 17: ...ire bed and allow the fire to burn over the entire area of the grate The ashpan should be emptied at least daily and ash should never be allowed to build up over a period of time as this will result i...

Page 18: ...air and will die down If you want to revive the fire it is recommended that the thermostat control is opened first and then the secondary air control Warning The stove will remain hot for a considera...

Page 19: ...lace a glass panel please ensure you purchase a new Gasket at the same time Please check periodically that the glass clips and screws have not become loose GASKETS All gasket used on this appliance ar...

Page 20: ...flue system will cause poor performance of your appliance Excessive Flue Draught can cause low heat output Poor burning control excessive fuel consumption and even noise from the Air Controls Low Flu...

Page 21: ...B 05 03 15 Spares Information SINGLE DOOR SINGLE DOOR HCE09008 DOOR HANDLE ASSEMBLY TDI05ARRT011MB DOOR GLASS HCE09102 ROPE SEALING KIT SCPCB900SDRSK REVC GLASS GASKET HCE09101 GLASS CLIP HHR08046 SC...

Page 22: ...ASS HCE09031 ROPE SEALING SCPCB900DRSK GLASS GASKET HCE09030 GLASS CLIP HHR08046 SCREW FSJM05008SS RIGHT HAND DOOR HCE09009 DOOR HANDLE ASSEMBLY TDW09ARRT011MB GLASS CLIP HHR08046 SCREW FSJM05008SS GL...

Page 23: ...UPPER P112032 LOWER P112033 OPERATING TOOL HFR07040 FUEL RETAINER HCW09ARRT025 HINGE PIN FRRE08 1 75 HINGE HH06050 BRICK LEFT HCW09051A RIGHT HCW09051B SLIDER KNOB HCE05040M BAFFLE HCW09ARRT011 CAM B...

Page 24: ...NFORMATION Date Installed Appliance Stock Code Appliance Description Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney f...

Page 25: ...ervicing Company Engineer Signature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Si...