Model 47999B

Congratulations!

Your new Hunter thermostat will provide years of reliable service.  

Using this digital thermostat will provide more uniform comfort in 

your home through the seasons.  Thank you for buying a Hunter 

product! 
Please read this manual for complete instructions on installing and 

operating your thermostat. If you require further assistance, call 

Hunter   Technical  Support  at  1-888-830-1326  from  8am  to  5pm 

Central Time.
Remove the mylar label from the display window.

IMPORTanT InfORMaTIOn

1.  This thermostat is designed to work on the following systems:

•  Gas - Standing Pilot

•  Gas - Electronic Ignition

•  Oil - Fired Boilers

•  Oil - Fired Furnace

•  Electric Furnace

•  Electric Air Conditioning

This thermostat will nOT control single-stage or multi-stage heat 

pumps or 110/220 V baseboard electric heating systems.
2.  Temperature Range
This thermostat can be set between 45°f and 95°f (7°C and 35°C). 

However, it will display room temperatures from 30°f to 99°f (0°C 

and 37°C). “HI” will be displayed if the temperature is higher than 

99°f (37°C), and “LO” will be displayed if the temperature is lower 

than 30°f (0°C).
This thermostat will automatically cutoff in Heat mode if the tem-

perature rises above 95°f (35°C), and automatically cutoff in Cool 

mode if the temperature drops below 45°f (7°C). 
3.  Compressor Protection
This thermostat provides a 3.5 minute delay after shutting off the 

cooling system before it can be restarted. This feature will prevent 

damage to your compressor caused by rapid cycling. It does not 

prevent a rapid compressor restart due to short power outages.
4.  Battery Warning
Two fresh aa alkaline batteries should provide well over one year 

of service. However, when the batteries become drained, the Low 

Battery Indicator will flash on the display. When this message occurs, 

install new alkaline batteries. You have approximately 1 minute to 

change the batteries and keep the thermostat’s settings. Once the 

batteries have become too low to ensure proper operation, your 

system will be turned Off, and the display will be cleared except for 

flashing Low Battery Indicator on the LCD display.
CAUTION: When only the battery icon flashes on the display, the 

thermostat is shut down, and your system will no longer operate. In 

this condition, there is no temperature control of your dwelling.

NOTE: If you plan to be away from the premises over 30 days, we 

recommend that you replace the old batteries with new alkaline 

batteries prior to leaving.

FEATUrES

InSTaLLaTIOn

•  Gas - Fired Boilers

•  Gas - Milivolt Systems

JUST rIGhT

DIGITAL ThErMOSTAT

LCD Display: 

Shows Room 

Temperature, 

Set Tempera-

ture, and other 

feature informa-

tion as required.

Low Battery In-

dicator: flashes 

when batteries 

need to be 

replaced.

filter Change 

Indicator: flashes 

when filter needs 

to be checked.

Front Doors: 

Covers keys 

and batteries 

when not 

used for neat 

appearance. 

Open with one 

finger from top 

or bottom.

Reset: Press with a 

paper clip to reset the 

thermostat and return 

to power-up settings.

System 

Switch: 

Selector 

switch for 

Heat, Cool, 

and Off.

fan Switch: 

fan switch for 

automatic or 

Continuous 

fan operation.

Battery Compart-

ment: 

front access al-

lows easy insertion 

of two aa 1.5V 

batteries.

Up and Down 

Keys: Keys for 

changing the 

Temperature 

setting. also 

used for adjust-

ing the Span.

filter 

Key: 

Resets 

the filter 

change 

counter to 

zero.

What You need

This thermostat includes two #8 slotted screws and two wall anchors 

for mounting. To install your thermostat, you should have the fol-

lowing tools and materials.

•  Slotted Screwdriver(s) 

•  Small Philips screwdriver

•  hammer

•  Electric drill and 3/16” bit

•  Two 1.5 V (AA) size alkaline batteries

Remove Old Thermostat

CAUTION:  Do  not  remove  any  wiring  from  existing  thermostat 

before  reading  the  instructions  carefully.  Wires  must  be  labeled 

prior to removal.
IMPORTanT! Turn off the power to the furnace at the main power 

panel or at the furnace.
Remove existing thermostat cover and thermostat. See figure 1. 

Some thermostats will have screws or other locking devices that 

must first be removed. Once the wall mounting plate is exposed, 

look for wires.
If wires are not visible, they may be connected to the back of the 

wallplate. again, look for screws, tabs, etc. Some models have doors 

that open to expose wires and mounting screws. See figure 1.

Typical Home Thermostats

figure 1

Wire Labeling

•  Each wire coming from the wall to the existing thermostat is 

connected to a terminal point on that thermostat. Each of these 

terminal points is usually marked with a code letter as shown in 

Table a below.

•  The number of wires in your system can be as few as two (for 

heat only systems), as many as eight, or any number in between. 

If you follow the labeling procedures correctly, you do not have 

to be concerned about how many wires there are.

•  There is often no terminal marking on the existing thermostat of 

two wire, heat only systems. Just connect either of the wires to 

the Rh terminal, then connect the other wire to the W terminal 

to complete the circuit.

•  IMPOrTANT! BEFOrE DISCONNECTING ANY WIrES, APPLY 

ThE SELF-ADhESIVE LABELS PrOVIDED TO ThE WIrE AS 

ShOWN IN TABLE A BELOW. (For example, attach the label 

marked W to the wire that goes to the W or H terminal on your 

existing thermostat.) IGNOrE ThE COLOr OF ThE WIrES 

since these do not always comply with the standard.

•  After labeling wires, disconnect them from the existing thermostat 

terminals.

•  remove existing wallplate. To make sure wires do not fall back 

into wall opening, you may want to tape them to the wall.

•  If hole in wall is larger than necessary for wires, seal this hole 

with insulating material so that no hot or cold air can enter the 

back of the thermostat from the wall. This air could cause a false 

thermostat reading.

Table a

NOTE: Do not connect a “Common” wire (sometimes labeled “C”) 

to any terminal on this thermostat. Tape up the wire and do not use. 

This wire provides electricity to non-battery powered thermostats.

If the code letter on 

your existing thermo-

stat is

then mark the wire 

with label shown

and connect to 

thermostat terminal 

shown

RH, R, VR or 4 

24 Volt

RC, VC

24 Volt Cool

G or F

fan

Y, C or M

air Conditioning Com-

pressor

W or H

Heating

figure 2

•  Position wallplate on wall and pull existing wires through large 

opening. Then level for appearance. Mark holes for plastic an-

chors provided, if your existing holes do not line up with those 

on the wallplate.

•  Drill holes with 3/16” bit and gently tap anchors into the holes 

until flush with wall.

•  reposition wallplate to wall, pulling wires through large opening. 

Insert mounting screws provided into wall anchor and tighten. 

See figure 3.

figure 3

NOTE: 5-wire Systems

If your thermostat has one wire marked R or Rh (2, 3, or 4-wire 

system), then leave the jumper wire between the Rh and Rc termi-

nals on the wallplate. Otherwise, if you have separate Rh and Rc 

wires (5-wire system), then remove the jumper wire between the 

Rh and Rc terminals.

Connect Wires and Mount Thermostat to 

Wallplate

•  Match and connect the labeled wires to the appropriate coded 

terminal screws on the wallplate. (See figure 4, 5.) Ignore any 

wires which may be present, but which were not connected to 

the old thermostat.

figure 4

figure 5

•  refer to the Wiring Diagrams below to be sure your system is 

wired correctly.

•  Be  sure  to  tighten  the  terminal  screws  securely,  otherwise  a 

loose wire could cause operational problems with your system 

or thermostat.

•  Push excess wire back into the hole to prevent interference when 

installing the thermostat to the wallplate.

•  Make sure the System Switch is set to OFF, and the Fan Switch 

is set to aUTO.

•  Insert the tabs on top of the thermostat body into the slots at the 

top of the wallplate. Press the bottom of the thermostat body 

into the snap on the bottom of the wallplate. Refer to figure 2. 

(NOTE: Do not force the thermostat onto the wallplate, as the 

terminal pins may be damaged. If it does not snap properly, the 

thermostat may not work.)

•  Insert the two AA size alkaline batteries, observing the polarity 

marked inside the battery compartment.

•  Switch on the main power at the panel or furnace.

Mount Wallplate and Thermostat

•  remove  the  wallplate  from  your  thermostat  by  pressing  the 

release tab on the bottom of the thermostat.  See figure 2.

 form no. 42791-01 Rev 08-04-2008

Reviews: