Congratulations on purchasing 
your new Hunter® ceiling fan!  It will 
provide comfort and performance 

in your home or ofce for many 

years. This installation and operation 
manual contains complete 
instructions for installing and 
operating your fan.

We are proud of our work and 
appreciate the opportunity to 
supply you with the best ceiling fan 
available anywhere in the world.

To register your fan please visit:
www.HunterFan.com/register

30 inches

7 feet

P

A

G

E

2

What to Expect with 

Your Installation

Ceiling Bracket

Ladder

P

A

G

E

3

Tools Needed

P

A

G

E

6

Hanging the Fan

P

A

G

E

8

Motor Housing

Table of Contents

P

A

G

E

7

P

A

G

E

13 

Maintenance, 

Operation & Cleaning 

Troubleshooting

?

?

?

P

A

G

E

12

P

A

G

E

5

Preparation

P

A

G

E

4

Wiring

P

A

G

E

10

Switch Housing

Blades

P

A

G

E

9

1

M0047-01 • 11/26/12 • 

© Hunter Fan Company

www.HunterFan.com

1.888.830.1326

M0047-01 • 11/26/12 • 

© Hunter Fan Company

1.888.830.1326

1.888.830.1326

What to Expect with Your Installation

Know your wiring

If you are unfamiliar 
with wiring, use a 

qualied electrician.

You may need a 
friend to help you.

Check box to see 
fan weight

Assess location

30 inches

from blade tip 
to nearest wall 
or obstruction

7 feet

from bottom 

edge of blade 

to the oor

w.1 - To reduce the risk of re, electrical shock, or 

personal injury, mount fan directly from building 
structure and/or an outlet box marked acceptable for 
fan support of 70 lbs (31.8 kg) and use the mounting 
screws provided with the outlet box.

w.2 - To avoid possible electrical shock, before installing 
or servicing your fan, disconnect the power by turning 
off the circuit breakers to the outlet box and associated 
wall switch location. If you cannot lock the circuit 
breakers in the off position, securely fasten a prominent 
warning device, such as a tag, to the service panel.

w.3 - 

To reduce the risk of re, electrical shock, or motor 

damage, use only Hunter Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the 
blade brackets when installing the blade brackets, balancing 
the blades, or cleaning the fan. Do not insert foreign objects 
in between rotating fan blades.

c.1 - All wiring must be in accordance with national and 
local electrical codes ANSI/NFPA 70. If you are unfamiliar 

with wiring, use a qualied electrician. 

c.2 - Use only Hunter replacement parts.

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

CAUTIONS

Must be able to 
secure the fan to 
building structure or 
fan-rated outlet box

2

Summary of Contents for 51060

Page 1: ...hes from blade tip to nearest wall or obstruction 7 feet from bottom edge of blade to the oor w 1 To reduce the risk of re electrical shock or personal injury mount fan directly from building structur...

Page 2: ...the circuit breakers to the outlet box associated with the wall switch location Turn Power 4 Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64...

Page 3: ...88 830 1326 6 M0047 01 11 26 12 Hunter Fan Company Hanging the Fan While holding the wires out of the way lift the motor assembly and place the square hanger into the opening in the ceiling bracket Be...

Page 4: ...from the fan Connect the white wire grounded from the ceiling to the white wire from the fan Using an orange wire connector from the hardware bag connect the 3 grounding wires green green yellow stri...

Page 5: ...o prevent scratching Cleaning agents may damage the nishes www HunterFan com 1 888 830 1326 Feed the wire plug through the center hole of the upper switch housing then wrap keyhole slots around the sc...

Page 6: ...Turn Power Align the notches in the sides of the lower switch housing with the screws on the upper switch housing Twist the lower switch housing clockwise to lock into place Install the third switch...

Page 7: ...heck to see if any of the blades are cracked If so replace all of the blades Fan doesn t work Make sure power switch is on Pull the pull chain to make sure it is on Push the motor reversing switch rml...