6
45046-01 • 08/17/09 • Hunter Fan Company
You can assemble your fan for
standard
or
angled
mounting as shown
in steps 3-1 – 3-3. For
low profile
mounting (ceilings less than 8 feet
high), go to steps 3-6 – 3-9 on the next page.
3-1. To assemble fan to hang down from a flat or angled ceiling, place
the canopy and canopy trim ring around the adapter so that they
rest on the fan assembly.
3-2. Feed the wires from the fan through the downrod.
Note:
Make sure all the wires are on the same side of the metal
dowel pin inside the dowrod.
3-3. Loosen the square head setscrew on the adapter to install the pipe
and ball assembly.
Note:
When the pipe and ball assembly is fully
installed, 2-3 threads on the pipe will still be visible; this is normal.
Securely retighten the setscrew with a wrench or pliers.
CAUTION:
The adapter has a special coating on the threads. Do
not remove this coating; the coating prevents the downrod from
unscrewing. Once assembled, do not remove the downrod.
WARNING:
Do not carry or lift fan by canopy.
3-4. Raise the fan and place the ball into the hanger bracket.
3-5. Align the notch on the ball with the indent in the hanger bracket.
(Rotate the fan until you hear the notch pop into place.)
Go to
4 • Wiring the Fan .
WARNING:
Fan may fall if not assembled as directed in these
installation instructions.
Steps 3-4 – 3-5
Indent
Steps 3-1 – 3-3
Downrod
Canopy
(with Washer)
Canopy
Trim
Ring
Setscrew
Adapter
3 • Assembling and Hanging the Fan