background image

43003-01 

10 

Air Purifier Maintenance

 

11 

43003-01

Air Purifier Maintenance

Cleaning Your Air Purifier

Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free 

service. 

Follow these steps to properly maintain your Air Purifier:
  1.  Approximately every 90 days, the outside of the unit should be cleaned with a 

soft, damp cloth. 

  2.  If needed, the Front Grill can be removed from the unit and cleaned with soapy 

water. Simply remove the Pre-Filter before exposing the Grill to water.

  3.  Follow the instructions in Changing the Pre-Filter and Changing the Filter (pgs. 

10 and 11) to determine when and how to replace the filters.

NOTES:

 

• The Air Purifier must be unplugged during the cleaning process.
• Be sure the unit is completely dry before plugging in and using.
• Never immerse unit in water.

Changing the Pre-Filter

When the Pre-Filter exceeds 1400 hours (refer to Filter Life Counters for additional 

information, pg. 8), the Pre-Filter Indicator will turn on as a reminder that you should 

replace the Pre-Filter. To maintain proper odor-removing capability and overall filtra

-

tion performance, the Pre-Filter should be changed every 1400 hours (approximately 

3 months of use). If necessary, the Pre-Filter can be changed more often. Proper 

maintenance of the Pre-Filter will help extend the life of the HEPAtech

®

 filter. Refer to 

Obtaining Replacement Filters (pg. 16) if you need help finding replacement filters. 

To change the Pre-Filter and reset the Pre-Filter Life Counter:
 

1. First, turn off and unplug the Air Purifier.

 

2. Next, remove the Front Grill.  Place your fingers under the handle on 

the Grill and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).

 

3. The Pre-Filter is attached to the inside of the Grill with hook tape. Pull 

gently on the Pre-Filter to remove it. Refer to Fig. 9.

 

4. If needed, use a soft damp cloth to wipe off the Grill.

 

5. Install the new Pre-Filter by placing it in the Grill and pressing gently on 

the Pre-Filter so that it adheres to the hook tape. You may notice a few 

black particles coming off the Pre-Filter. Those particles are part of the 

odor-removing activated carbon and will be collected on the filter during 

regular use.

Fig. 9

PRE-FILTER

HOOK 

TAPE

 

6. Place the Front Grill back onto the unit. First, line up the tab on the bottom 

of the Grill with the recess on the purifier base and then push the top of 

the Grill forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: 

This unit will not operate unless the Grill is in the correct position.  

 

7. Plug in the Air Purifier.

 

8. To reset the counter to zero hours and turn off the indicator, simply press 

and hold the PRE-FILTER RESET

 key for three seconds. Then, you 

must release the reset key and then press and hold the Pre-Filter reset 

key again for three seconds to turn off the filter indicator.

Changing the Filter

When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter 

indicator will turn on as a reminder that you should replace the filter. (Refer to Filter 

Life Counters for additional information, pg. 8.) This is a reminder that you should 

check the Filter and replace if necessary. The proper time to change the Filter de

-

pends on usage and the environment. Use the following list to help determine if the 

filter should be changed:

• Compare the color of the Filter to the color coded chart on the inside of the hous

-

ing. If the Filter color matches the darkest color on the chart, you should replace 

the Filter.

• If you notice a decrease in air output or an increase in noise at any time during 

normal operation, the Filter may be clogged. Replace the Filter to return to normal 

operation.

Continued

Summary of Contents for HEPAtech Plus 30760

Page 1: ... 01 24 2008 2008 Hunter Fan Company HEPAtech Plus Air Purifier Model 30760 Replacement Filter Information Pre Filter 30901 HEPAtech Filter 30963 Replacement UVC Lamp Information www hunterfan com Model 30760 UVC Lamp 30899 ...

Page 2: ... section of this manual pg 10 8 This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that could result in flashover or risk of fire Introduction Thank you for purchasing the HEPAtech Plus Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to impro...

Page 3: ...ctivated carbon Pre Filter absorbs odors and catches large particles Then the air travels through the HEPAtech filter where the smaller particles are collected Next the air passes through the UVC Field which helps reduce airborne pathogens such as germs viruses mold and mildew Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Final...

Page 4: ...during shipping To check the filters first open the Front Grill Release the Front Grill by placing your fingers under the handle on the Grill and pull forward then up Refer to Figs 4 and 5 Fig 4 Fig 5 3 Next check the HEPAtech filter by pressing firmly on all four corners of the Filter to ensure that it is fully inserted into the filter opening NOTE THIS UNIT WILL NOT OPERATE UNLESS FILTER IS INST...

Page 5: ...tructions on how to reset the counters Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the Air Purifier If you still have problems after resetting the Air Purifier please contact Hunter for additional assistance refer to Technical Support pg 17 To Reset the Air Purifier 1 Unplug the unit for at least 30 seconds 2...

Page 6: ...f the Grill with hook tape Pull gently on the Pre Filter to remove it Refer to Fig 9 4 If needed use a soft damp cloth to wipe off the Grill 5 Install the new Pre Filter by placing it in the Grill and pressing gently on the Pre Filter so that it adheres to the hook tape You may notice a few black particles coming off the Pre Filter Those particles are part of the odor removing activated carbon and...

Page 7: ...l not operate unless the Grill is in the correct position 6 Plug in the unit 7 To reset the counter to zero hours and turn off the indicator simply press and hold the Filter Reset key for three seconds Then you must release the Filter Reset key and then press and hold the Filter Reset key again for three seconds to turn off the Filter Indicator Fig 10 Changing the UVC Lamp When the UVC Lamp exceed...

Page 8: ...HE LAMP COVER IS NOT INSTALLED CORRECTLY 10 Install the Lamp Cover Screws 11 Press the filter firmly into the Air Purifier To avoid damaging the filter media you should press on the frame of the filter only Refer to page 12 NOTE THIS UNIT WILL NOT OPERATE UNLESS FILTER IS IN STALLED CORRECTLY AND SEATED PROPERLY 12 Place the Front Grill back onto the unit First line up the tab on the bot tom of th...

Page 9: ... the Pre Filter on pg 10 and Changing the Filter on pg 11 4 Unit has reduced air flow or increased noise The filter is clogged and should be changed Refer to Changing the Filter on pg 11 Obtaining Replacement Filters and UVC Lamps To obtain replacement filters for your Air Purifier first determine your model number by looking at the information label on the back of the Air Purifier The model numbe...

Page 10: ... were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling modifications or damage to the Air Purifier while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance This warranty does not cover Air Purifiers used in commercial applications There are no express or implied warranties as to comm...

Page 11: ... see our Web page at www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 43003 01 Printed in China and Taiwan M AM 4 TEMP ...

Reviews: