Operation, Maintenance, & Cleaning

Reverse 

Switch

To switch the direction of air flow, move the 

reverse switch to the opposite position. 

•  Press the Fan Off button for at 

least three seconds to initiate the 
Safe-Exit Mode.

•  The lights will flash for visual 

confirmation.

•  The lights will stay on 50% 

brightness for 15 seconds and 
then begin to dim. After a total 
of 30 seconds, the lights will be 
completely off.

Note: 

 For CFL lighting, the lights 

will stay on 100% brightness for 30 
seconds. After a total of 30 seconds, 
the lights will be completely off.

The Safe-Exit Program gives 
you about thirty seconds of light 
when you turn the lights off to 
exit the room before the lights go 
out. To use Safe-Exit:

Safe-Exit

For cleaning the fan, use soft brushes or 

cloths to prevent scratching. Cleaning 

products may damage the finishes.

14

MB502-01 • 03/25/14 • 

© Hunter Fan Company

Summary of Contents for MB502-01

Page 1: ...MB502 01 03 25 14 Hunter Fan Company www HunterFanInternational com ENGLISH ...

Page 2: ......

Page 3: ...tions on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Remote Control PA G E 13 PA G E 6 Down...

Page 4: ...void possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter ...

Page 5: ...ll also need these tools If you are installing multiple remote controlled fans on the same circuit breaker you may need to perform a few extra steps to prevent interference or faulty operation of your remote controls Go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for more information 3 MB502 01 03 25 14 Hunter Fan Company ...

Page 6: ...u need ONLY a Longer Downrod most common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting to hang the fan from a flat ceiling Use Angled Mounting to hang the fan from a vaulted or angled ceiling 34O CEILING WALL OPTION 1 Standard Mounting OPTION 2 Angled Mounting 2 3 SLIDE toward ceiling PLACE against wall 1 FOLD on dotted line 34 Use t...

Page 7: ...e sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is a...

Page 8: ...onger Downrod for angled ceilings or ceilings 3 m 10 or higher Standard Downrod for ceilings 2 4 3 m 8 10 high Option 1 Option 2 skip to next page Included pre assembled If you need a longer downrod follow the steps in the Instructions for Installing a Longer Downrod manual included with your fan ...

Page 9: ... but leave at least 20 cm 8 extending from the top of the downrod 20 cm 8 1 cm 3 8 DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan 7 MB502 01 03 25 14 Hunter Fan Company ...

Page 10: ...connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the blue wire connectors from the remote control hardware bag connect the white wire from the receiver marked common out to the white wire from fan Connect the black wire from the receiver marked fan out to the black wire from the fan Connect the blue wire from the recei...

Page 11: ... when lifted into place the canopy fits into the hanging bracket as shown Note Fan style may vary Lift the canopy into place so that the screw holes are aligned Screw Holes Insert the two canopy screws found in the hardware bag 9 MB502 01 03 25 14 Hunter Fan Company ...

Page 12: ...l com Blades Attach each blade to the fan using two blade grommets found in the hardware bag and two blade assembly screws found in the hardware bag Insert a blade into the motor housing 10 MB502 01 03 25 14 Hunter Fan Company ...

Page 13: ...in the light fixture falling Partially install two of the light kit assembly screws found in the hardware bag Align the keyholes in the light kit ring with the partially installed screws Lift the light kit ring in place and rotate counterclockwise to situate the screws in the narrow ends of the keyholes Install the third switch housing screw Tighten all three screws securely Switch Housing Screw ...

Page 14: ... globe in a clockwise direction until it is held tightly in place by the three tabs CONGRATULATIONS YOU RE DONE See next page for fan operation instructions Position the notches in the outer rim of the globe so they line up with the tabs on the light kit ring Notch Tab Install a 20W max CFL bulb in each socket Bulb 12 MB502 01 03 25 14 Hunter Fan Company ...

Page 15: ...he switch cover plate Do not remove the cover plate Orient the cradle by lining up the two mounting holes with those on the cover plate Insert and tighten the screws Do not over tighten Note For rocker style cover plates break off the tabs by pushing outward To turn on fan press a fan speed button Speeds range from off 0 to high 3 Quickly press the Light button to turn the lights off and on Medium...

Page 16: ...conds and then begin to dim After a total of 30 seconds the lights will be completely off Note For CFL lighting the lights will stay on 100 brightness for 30 seconds After a total of 30 seconds the lights will be completely off The Safe Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out To use Safe Exit Safe Exit For cleaning...

Page 17: ...y Turn off power from the circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 8 Check the plug connection in the switch housing Lights dim when turned on or do not turn on at all Make sure the wattage of the light bulbs installed matches the specifications on the light sockets Remote control of fan is erratic Make sure the battery is install...