Downrod

If you need a different downrod length follow these steps:

Follow steps 1-5 to remove standard downrod pipe

Follow steps 6-10 to reassemble with new downrod

1

2

3

4

5

6

7

8

9

10

WARNING

FAN FALL HAZARD

  

To prevent 

SERIOUS INJURY

 or 

DEATH:

 

• ALWAYS

 

follow the downrod assembly 

instructions exactly.

• VERIFY

 the downrod is assembled correctly 

by firmly pulling on the hanger ball.

Summary of Contents for Rhinebeck 50769

Page 1: ...Installation Manual 2019 Hunter Fan Co Model 50769 Noble Bronze 50773 Matte Silver Fan weight 2 lbs 16 4 lbs 7 4 kg Rhinebeck PG3857 r121819...

Page 2: ...risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades Caution...

Page 3: ...the hanger bracket and wiring the fan For installing the canopy Canopy Canopy Screw Ceiling Bracket Wood Screw Wire Nut Washer bag Hunter Pro Tip Find a part that is missing or damaged Don t take it b...

Page 4: ...port Structure Ceiling Outlet Box required Angled Mounting If you have a flat ceiling Hang your fan by a standard downrod Some fans come with a shorter downrod for a Low Profile installation Support S...

Page 5: ...hat came pre assembled in your box Need to install a longer or shorter downrod Check out the guide at the end of this manual 1 STEP Slide the adapter cover onto the downrod until it rests against the...

Page 6: ...wires Place the downrod ball into the slot in the ceiling bracket NOTICE To prevent damage to fan ALWAYS lift holding either the fan housing or the downrod Ceiling Bracket Downrod Hanging Fan Wiring...

Page 7: ...bare metal ends of the wires together and slide a wire nut over them Then twist the wire nut clockwise until tight Give it a gentle pull to make sure none of the wires are loose WARNING All wiring mu...

Page 8: ...t Remote Troubleshooting NOTICE If screw holes do not align properly then rotate the canopy 180 degrees Hanger ball shape must match canopy opening for correct canopy installation Fan style may vary N...

Page 9: ...sing then wrap keyhole slots around the screws and twist counterclockwise WARNING FAN FALL HAZARD Make sure all screws are tight to secure the light fixture 2 of 3 Light Kit Screw bag 1 of 3 Light Kit...

Page 10: ...is complete when LED button flashes twice To select fan speed press one of the numbers on the Fan Speed Dial To calibrate the fan speed run the fan on 6 for 90 seconds after each AC power reset The L...

Page 11: ...r One Year Limited Warranty Except as otherwise indicated throughout this warranty if any part of your Hunter ceiling fan fails at any time within one year of the date of purchase due to a defect in m...

Page 12: ...remove standard downrod pipe Follow steps 6 10 to reassemble with new downrod 1 2 3 4 5 6 7 8 9 10 WARNING FAN FALL HAZARD To prevent SERIOUS INJURY or DEATH ALWAYS follow the downrod assembly instru...

Reviews: