background image

1886

Ladder

9/64” Drill Bit

Drill

Screwdriver

Pliers

Wire Strippers

OPTIONAL

If mounting to a support structure, you will also need these tools.

Congratulations on purchasing your new Hunter

®

 ceiling fan!

Here are the tools you’ll need to complete your installation:

1

The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains 
complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the 
best ceiling fan available anywhere in the world.

We are here to help!

This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep 
your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or 
uncomfortable with wiring, contact a qualified electrician. We also provide telephone support at 1.888.830.1326 or visit us  
at HunterFan.com.

WARNING

READ and SAVE These Instructions

Warning

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the 

mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you 

cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3 – To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between 

rotating fan blades.

Caution

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. 
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions 

may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

•  Reorient or relocate the receiving antenna. 
•  Increase the separation between the equipment and receiver. 
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
•  Consult the dealer or an experienced radio/TV technician for help.

Caution: modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation.

This product conforms to UL Standard 507.

© 2019 Hunter Fan Company 
7130 Goodlett Farms Pkwy, Suite 400
 Memphis  TN  38016

Summary of Contents for Rhinebeck 50769

Page 1: ...Installation Manual 2019 Hunter Fan Co Model 50769 Noble Bronze 50773 Matte Silver Fan weight 2 lbs 16 4 lbs 7 4 kg Rhinebeck PG3857 r121819...

Page 2: ...risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades Caution...

Page 3: ...the hanger bracket and wiring the fan For installing the canopy Canopy Canopy Screw Ceiling Bracket Wood Screw Wire Nut Washer bag Hunter Pro Tip Find a part that is missing or damaged Don t take it b...

Page 4: ...port Structure Ceiling Outlet Box required Angled Mounting If you have a flat ceiling Hang your fan by a standard downrod Some fans come with a shorter downrod for a Low Profile installation Support S...

Page 5: ...hat came pre assembled in your box Need to install a longer or shorter downrod Check out the guide at the end of this manual 1 STEP Slide the adapter cover onto the downrod until it rests against the...

Page 6: ...wires Place the downrod ball into the slot in the ceiling bracket NOTICE To prevent damage to fan ALWAYS lift holding either the fan housing or the downrod Ceiling Bracket Downrod Hanging Fan Wiring...

Page 7: ...bare metal ends of the wires together and slide a wire nut over them Then twist the wire nut clockwise until tight Give it a gentle pull to make sure none of the wires are loose WARNING All wiring mu...

Page 8: ...t Remote Troubleshooting NOTICE If screw holes do not align properly then rotate the canopy 180 degrees Hanger ball shape must match canopy opening for correct canopy installation Fan style may vary N...

Page 9: ...sing then wrap keyhole slots around the screws and twist counterclockwise WARNING FAN FALL HAZARD Make sure all screws are tight to secure the light fixture 2 of 3 Light Kit Screw bag 1 of 3 Light Kit...

Page 10: ...is complete when LED button flashes twice To select fan speed press one of the numbers on the Fan Speed Dial To calibrate the fan speed run the fan on 6 for 90 seconds after each AC power reset The L...

Page 11: ...r One Year Limited Warranty Except as otherwise indicated throughout this warranty if any part of your Hunter ceiling fan fails at any time within one year of the date of purchase due to a defect in m...

Page 12: ...remove standard downrod pipe Follow steps 6 10 to reassemble with new downrod 1 2 3 4 5 6 7 8 9 10 WARNING FAN FALL HAZARD To prevent SERIOUS INJURY or DEATH ALWAYS follow the downrod assembly instru...

Reviews: