OPERATION

Energy Monitor

energy

Usage

Hr

Min

Today

energy

The Energy monitor feature measures and stores the
amount of time the heating and air conditioning sys-
tem operates. Usage can be displayed for Today (since
12am), Yesterday, This Week (since Monday), Last
Week (last Monday through Sunday), and Total (up to

999 Hrs. 59 Min.). By monitoring your energy
usage, you see how much the set-back periods
are saving and you can test program adjustment
to save even more. Use table on page 17.

To review energy usage, press to cycle through To-
day, Yesterday, This Week, Last Week, and Total.
Press again to return to normal mode, or wait 15
seconds for the display to return to normal mode.
You can also return to normal mode at any time by
pressing RETURN.

For example: This LCD display shows Today’s usage
to be 10 Hours, 26 minutes.

Press and hold for 3 seconds to reset the Energy
Monitor’s counters. The display will blink, and all
counters will be cleared to zero.

NOTE: 

Clearing the Energy Monitor counter will also clear the Filter Monitor counter, as Filter

usage and Total Energy usage are the same. Also, clearing the Filter Monitor counter will
clear ALL Energy Monitor counters as well.

41665-01.pmd

9/30/03, 4:53 PM

30

Summary of Contents for Set & Save 47300A

Page 1: ...Owner s Manual Model 47300A Programmable Thermostat M AM 4 TEMP 41665 01 pmd 9 30 03 4 52 PM 1 ...

Page 2: ...lete instructions on installing and operating your thermostat If you require further assistance call Hunter Techni cal Support at 1 866 268 1936 from 8 a m to 5 p m Central Time Model Information Model Number ___________________________________________ Serial Number____________________________________________ Date Purchased __________________________________________ Where Purchased _______________...

Page 3: ...Wall Plate 12 Selector Switches 13 Setting Time and Day 14 Default Programs 16 Personal Program Schedule 17 Manual Programming 18 Weekday Weekend Programming 19 7 Day Programming 21 Reviewing Programs 22 Reviewing the Current Temperature Setting 23 System Selector Switch 24 Fan Switch 24 Temporary Manual Override 25 INTRODUCTION INSTALLATION PROGRAMMING OPERATIONS continued 41665 01 pmd 9 30 03 4 ...

Page 4: ...32 SPAN Setting Mode 34 Low Battery Warning 36 Error Mode 37 Auto Cut Off 37 Problems Solutions 38 Technical Support 39 Heat Cool Systems 40 Single Stage Heat Pump Systems 41 Heat Only Cool Only Systems 41 42 Table of Contents continued OPERATIONS continued SAFETY FEATURES TROUBLESHOOTING WIRING DIAGRAMS 41665 01 pmd 9 30 03 4 52 PM 4 ...

Page 5: ...lt control systems and represent most central heating air conditioning or space heating units in use in the United States This Hunter Thermostat will NOT control multi stage heat pumps or 110 220 Volt systems COMPRESSOR PROTECTION 5The thermostat provides a 3 5 minute delay after shutting off the heating or cooling system before it can be restarted This feature will prevent damage to your compress...

Page 6: ...display When this message occurs install 2 new AA batteries You have approximately 1 minute to change the batteries and keep thermostat s clock and program settings Once the batteries have become too low to ensure proper operation your system will be turned Off and the display will be cleared except for the Low Battery indicator flashing on the LCD display CAUTION Once the Low Battery only display...

Page 7: ... switch for Automatic or Continuous fan operation Battery Release Lever Push to pop batteries loose Hold Return Key Used for setting a permanent or vacation hold and for returning to the normal display from Day Time setting Programming or Span setting modes Day Time Key Used for entering the Clock setting mode Use with the Up and Down keys to set the time and day Filter Key Resets Filter Change co...

Page 8: ...LABELED PRIOR TO REMOVAL IMPORTANT Turn off the power to the furnace at the main power panel or at the furnace Remove existing thermostat cover See Figure 1 Some thermostats will have screws or other lock ing devices that must first be removed Once wall mounting plate is exposed look for wires If wires are not visible they may be connected to the back of the wallplate Again look for screws tabs et...

Page 9: ...marking on the existing thermostat of two wire heat only systems Just connect either of the wires to the RH terminal then connect the other wire to the W terminal to complete the circuit IMPORTANT BEFORE DISCONNECTING ANY WIRES APPLY THE SELF ADHESIVE LABELS PRO VIDED TO THE WIRE AS SHOWN IN TABLE A ON THE NEXT PAGE For example attach the label marked W to the wire that goes to the W or H terminal...

Page 10: ...Volt Cool G or F Fan Y C or M Air Conditioning Compressor or O Reversing Valve operating in Cool mode Single Stage Heat Pumps ONLY If the code letter on your existing thermostat is then mark the wire with label shown and connect to thermostat terminal shown W or H Heating or B Reversing Valve operating in Heat mode Single Stage Heat Pumps ONLY Y1 Heat Pump compressor Single Stage Heat Pumps ONLY x...

Page 11: ...l holes with 3 16 bit and gently tap anchors into the holes until flush with wall Reposition wallplate to wall pulling wires through large opening Insert mounting screws provided into wall anchor and tighten See Figure 3 Figure 2 Figure 3 NOTE 5 wire Systems If your thermostat has one wire marked R or RH 4 wire system then leave the jumper wire between the RH and RC terminals on the wallplate Othe...

Page 12: ...h Be sure to tighten the terminal screws securely otherwise a loose wire could cause operational problems with your system or thermostat Push excess wire back into the hole to prevent interfer ence when installing the thermostat to the wallplate Make sure the System Switch is set to OFF and the Fan Switch is set to AUTO Insert the bottom tab on the thermostat body into the slot at the bottom of th...

Page 13: ...change the switch position to HE The system selector has no effect in the cool ing mode NOTE HG position is for gas and most other systems HE position is for certain electric systems having a fan relay Furnace or Heat Pump selector STD HP switch The factory position for this switch is in the STD position Leave it in this position if you have ANY system that uses gas oil electric or hot water heati...

Page 14: ...time of 2 16 pm on Saturday Refer to the Steps below STEP 1 Press to enter time and day setting mode The cur rent hour and the AM PM indicator will be flashing Press to change the Hour up or down to the current hour Note the AM PM indicator as the display will change at 12 AM and 12 PM STEP 2 Press again to change from hour setting to minute setting The current minute will be flashing Press to cha...

Page 15: ...EP 4 Press again to change back to the normal display NOTE You may press hold return at any time during Day and Time setting to return to the normal display DAYLIGHT SAVING TIME Press and hold Press to enter Daylight Saving Time PM M TEMP PM SA 2 day time day time hold return or TEMP 2 AM SA SET TEMP day time or continued 41665 01 pmd 9 30 03 4 53 PM 15 ...

Page 16: ...i mate that setting your thermostat back 6 C 10 F for two 8 hour periods during winter can reduce your fuel bill by as much as 33 By setting your thermostat up 3 C 5 F for two 8 hour periods during summer you can reduce your fuel bill up to 25 Your Hunter thermostat is pre programmed to meet the ENERGY STAR guidelines for energy efficiency The thermostat is pre programmed for all 7 days of the wee...

Page 17: ...emp Temp Temp Temp Wed Time Time Time Time Temp Temp Temp Temp Thurs Time Time Time Time Temp Temp Temp Temp Fri Time Time Time Time Temp Temp Temp Temp Sat Time Time Time Time Temp Temp Temp Temp Sun Time Time Time Time Temp Temp Temp Temp Cooling Day Prog 1 Prog 2 Prog 3 Prog 4 Mon Time Time Time Time Temp Temp Temp Temp Tues Time Time Time Time Temp Temp Temp Temp Wed Time Time Time Time Temp T...

Page 18: ... dem onstrates how to program your thermostat NOTE 1 The program time can be set in 10 minute increments and remains the same for both Heat and Cool programs 2 The program temperature can be set in increments of 1 C 1 F 3 After 15 seconds without a key press the thermostat will return to normal display mode 4 When setting the program time note the AM PM indicator 5 With the Auto Recovery feature e...

Page 19: ...ly dashes when the program key is pressed STEP 1 Press to enter program mode HEAT or COOL will be displayed on the LCD STEP 2 The Program hour and AM or PM indicator are flashing Press to change the hour STEP 3 Press again to change to the minute position The current minute will be flashing Press to change the minute system cool heat off program program 1 HEAT AM M TH W T F HEAT AM M TH W T F 1 41...

Page 20: ...ure STEP 5 Press again to move to the next program number Repeat steps 3 5 to change the remaining weekday programs STEP 6 Press to change to weekend programs Repeat steps 3 5 to change the weekend programs Press to exit Program mode or wait 15 seconds to exit automatically program program HEAT AM SA SU 1 prog day hold return 1 HEAT AM M TH W T F 41665 01 pmd 9 30 03 4 53 PM 20 ...

Page 21: ...o the next day s programs Repeat Step 2 to complete the selected day s programs Continue repeating Steps 2 and 3 to program all 7 days of the week STEP 4 When finished press to return to normal mode After 15 seconds the thermostat will return to normal mode automatically STEP 5 Change the System Selector Switch to the other system and repeat Steps 1 through 4 above system cool heat off program pro...

Page 22: ...rams Press repeatedly to cycle through the 4 programs Press to display M F programs NOTE Time and Temperature display will be blank when at least one weekday program is different Press to change to Sa Su Again if the display is blank one of the weekend programs is different Daily Programs program prog day program Weekday Programs Weekend Programs program HEAT AM M TH W T F 1 HEAT PM SA SU 3 M TH W...

Page 23: ... you are armchair programming the thermostat slide the system selector to the OFF position before mounting the thermostat to the wallplate Reviewing the Current Temperature Setting Current time and temperature Press for 1 second or less Set Temperature is shown above current room temperature If held for over 1 second Temporary Manual Over ride mode is entered Refer to the next page HEAT AM M 1 hol...

Page 24: ...sibility of a rapid system On Off Fan Switch The Fan switch should normally be located in the AUTO position The Fan will be turned on along with normal operation of your system In a normal gas or oil furnace the Fan will be turned on by your furnace after its warm up delay For electric heat air conditioning and heat pump operation the Fan will turn on with the system To run the Fan on continuously...

Page 25: ...eturn to normal mode or wait 5 seconds for it to return automatically The current program number will flash to signify the Temporary Override At the next program change time the Temporary Override is cancelled and the next program tem perature becomes the setpoint temperature To end the Temporary Manual Override Press and wait for HOLD to display on the LCD Press again This will return the set tem...

Page 26: ...e Program number will disappear Follow the Temporary Manual Override instructions above to change the Permanent Manual Override temperature You can confirm the held set temperature by press ing for less than 1 second To end the Permanent Manual Override Press again The thermostat will return to the current program and the HOLD display will be canceled hold return TEMP PM TH HOLD hold return 41665 ...

Page 27: ...ratures Press and hold for 2 seconds Display will change to show a 1 day hold Press to select the number of days to set the vacation hold temperature In this example 14 is used Press to set the desired temperature Press to return to normal mode or wait 5 seconds for it to return automatically HOLD will be shown on the LCD and VACA will alternate with the time day time hold return TEMP COOL SET TEM...

Page 28: ...emperature The display will flash HOME TODAY and the pro gram number will disappear When pressed during the first or second program of the day Home Today will automatically return to program control at the start of the fourth program of the day If Home Today is pressed after the start of the third program time of the day the thermostat will remain in Home Today mode until the first pro gram of the...

Page 29: ...played on the LCD screen and the thermostat returns to the current program You can manually change the setpoint temperature while in Home Today mode Refer to the Temporary Manual Override instructions on page 24 Manually changing the set temperature while in Home Today mode will not affect the Home Today ending time However the set temperature will not change automatically with a manual or Auto ma...

Page 30: ...age press to cycle through To day Yesterday This Week Last Week and Total Press again to return to normal mode or wait 15 seconds for the display to return to normal mode You can also return to normal mode at any time by pressing RETURN For example This LCD display shows Today s usage to be 10 Hours 26 minutes Press and hold for 3 seconds to reset the Energy Monitor s counters The display will bli...

Page 31: ...ER then show the Filter Monitor counter After 15 seconds the display will return to normal mode or you can hit RETURN to exit immediately The Filter Monitor will display up to 999 hours and 59 minutes of usage In this example the counter is at 410 Hours 26 minutes To reset the Filter Monitor counter depress FILTER for 3 seconds The display will blink and the counter will be reset to zero NOTE Clea...

Page 32: ...C instead of 16 C Auto Recovery Hunter s Auto Recovery feature meets the ENERGY STAR guidelines for energy efficiency by allowing the heating or cooling system to recover gradually from an energy saving setpoint temperature to a comfort setpoint temperature Auto Recovery calculates how early to turn your sys tem back On so that the room temperature is already comfortable by the start of the comfor...

Page 33: ...that if time or program is changed then the thermostat will check Auto Recovery conditions immediately Auto Recovery will be canceled and change to Home Today mode if HOME TODAY is pressed during the recovery process Auto Recovery will be canceled and change to Temporary Manual Override mode if the setpoint is adjusted during the recovery process If the system is changed between heat and cool then...

Page 34: ... you find your system cycling too fast or too slow then the Span can be adjusted to modify the cycle time Press and hold BOTH for three seconds The display will flash and SPAN will be displayed on the LCD Press to raise the Span to 3 This setting INCREASES the cycle time by allowing your system to run LONGER Press to lower the Span to 1 This setting DECREASES the cycle time by causing your system ...

Page 35: ...HEAT and COOL The Span can be changed at any time and is inde pendent of program times or temperatures When batteries are installed in the thermostat or the Reset key is pressed the Span is reset back to setting 2 41665 01 pmd 9 30 03 5 40 PM 35 ...

Page 36: ... become too weak for normal operation the thermostat enters the second stage low battery warning which shuts down the thermostat In this condition BATT flashes alone on the display and the thermostat will turn your system Off Your system will remain shut off until the batteries are replaced 3 HEAT TEMP PM T NOTE The thermostat will still keep the current time and your programs in memory until new ...

Page 37: ...r clip to press the RESET button next to the keypad You will need to reprogram your thermostat and confirm normal operation If Error Mode returns please call Hunter Technical support at 1 866 268 1936 for further information Auto Cut Off Your thermostat will automatically cut off in Heat mode if the room temperature rises above 35 C 95 F It will cut off in Cool mode if the room temperature drops b...

Page 38: ...or Home Today modes 3 Check for the correct day setting 1 Move HG HE selector to opposite position 1 Check that the system selector switch is in the correct position HEAT COOL 2 There may be as much as a 4 minute delay before the Heat or Cool system turns On wait and check Compressor protection delay 3 Check your circuit breakers and switches to ensure there is power to the system 4 Replace batter...

Page 39: ...O or ERR after pressing reset button 1 Press the RESET button once with a small pin and hold for two seconds The thermostat will need to be re programmed 1 Replace unit 1 Replace unit If you experience any other problems call 1 866 268 1936 from 8 AM to 5 PM Central Time for technical assis tance 41665 01 pmd 9 30 03 4 53 PM 39 ...

Page 40: ...ay Cool Contactor Heat Relay or Valve 24V Supply Heat Cool Rh Rc Y O W B Y1 G X X System Selector STD HP No Jumper Wallplate Terminals Fan Relay Cool 24V Supply Heat Relay or Valve Heat 24V Supply Rh Rc Y O W B Y1 G Cool Contactor X System Selector STD HP X No Connection 41665 01 pmd 9 30 03 4 53 PM 40 ...

Page 41: ...l See Table A System Selector STD HP Wallplate Terminals Rh Y O W B Rc G Fan Relay Reversing Valve Compressor Contactor Y1 Heat Pump 24V Supply Jumper X X X Wallplate Terminals Rh Rc Heat 24V or Millivolt Supply Heat Relay or Valve X Y O W B Y1 G System Selector STD HP X No Connection 41665 01 pmd 9 30 03 4 53 PM 41 ...

Page 42: ...an Relay Rh Rc Y O W B Y1 G Heat 24V Supply X Heat Relay or Valve System Selector STD HP 3 wire Cool Only Rh Rc Y O W B Y1 G Jumper X X Wallplate Terminals Cool Contactor Cool 24V Supply Fan Relay X System Selector STD HP X No Connection 41665 01 pmd 9 30 03 4 53 PM 42 ...

Page 43: ...ailer for Other Quality Products from Hunter To locate our nearest Hunter Dealer call 1 800 4HUNTER or visit The Hunter Fan Company website www hunterfan com Air Purifiers Fans Humidifiers 41665 01 pmd 9 30 03 4 53 PM 43 ...

Page 44: ... 2003 Hunter Fan Company Form No 41665 01 9 03 Hunter Fan Company Canada 45 BRAMALEA ROAD SUITE 207 BRAMPTON ONTARIO L6T 2W4 41665 01 pmd 9 30 03 4 53 PM 44 ...

Reviews: