background image

WARNING

DO NOT ALTER THE
ELECTRICAL PLUG. Plugging the
electrical plug into an unsuitable
supply circuit will damage the
equipment and may result in
personal injury.

When servicing the SmartWeight® Pro, power must
be disconnected by removing the power cord from
the electrical outlet.

Ensure that the SmartWeight® Pro power switch is
in the off position ("O" position) before plugging the
power cord into the electrical power outlet.

2.3. Important Safety
Instructions - Operation

To reduce the risk of fire, do not operate equipment
near open containers of flammable liquids
(gasoline).

Read and follow all caution and warning labels
affixed to your equipment and tools. Misuse of this
equipment can cause personal injury and shorten
the life of the equipment.

Keep all instructions permanently with the unit.

Keep all decals, labels, and notices clean and
visible.

To prevent accidents and/or damage to the
Balancerrecommended accessories.

Use equipment only as described in this manual.

Never stand on the Balancer.

Wear non-slip safety footwear when operating the
Balancer.

Keep hair, loose clothing, neckties, jewelry, fingers,
and all parts of body away from all moving parts.

ALWAYS WEAR OSHA APPROVED SAFETY
GLASSES. Eyeglasses that have only impact
resistant lenses are NOT safety glasses.

2.4. Important Safety Instruction
- Balancers

Keep the safety hood and its safety interlock system
in good working order.

Do not place any tools, weights, or other objects on
the safety hood while operating the balancer.

Verify that the wheel is mounted properly and that
the wing nut is firmly tightened before spinning the
wheel.

The safety hood must be closed before touching the
green “

START

” button, to spin the wheel.

Raise safety hood only after wheel has come to a
complete stop. If safety hood is raised before the
spin is com-pleted, the weight values will not be
displayed.

The red “

STOP

” button, can be used for emergency

stops.

2.5. Decal Information &
Placement - Balancers

• Decal 128-1244-2 cautions the operator that

spindle rotation may occur with foot pedal
depression and to keep clear of clamping
components during shaft rotation.

• Decal 128-964-2 gives the maximum wheel

diameter and maximum wheel weight for the
SmartWeight® Pro.

• EN/IEC Class 1 Laser Product Certification is

shown on Decal 128-1638-2. This label shows the
EN/IEC standards for a Class 1 Laser Product.

• An explanation of FDA compliance standards is

shown on Decal 128-1117-2. FDA performance
standards compliance is shown on the decal.

• For units with TDC Laser, FDA standards for

Class 2M laser compliance are shown on Decal
128-1155-2.

• Decal 128-381-2 warns the operator not to

remove the covered of the SmartWeight® Pro
because of the risk of the electrical shock and not
to use below garage floor level.

• ETL certification standards are outlined on Decal

128-1120-2. Users are cautioned not to use the
balancer below garage level.

• A manufacturer's identification is also on the rear

of the balancer.

SmartWeight

®

 Pro Operations Manual

Page 3 of 8

Summary of Contents for SmartWeight Pro

Page 1: ...SmartWeight Pro Operations Manual 7641 T 09 21 ...

Page 2: ...RNING Warning Hazards or unsafe practices which could result in severe personal injury or death DANGER Danger Immediate hazards which will result in severe personal injury or death These symbols identify situations that could be detrimental to your safety and or cause equipment damage 2 2 Important Safety Instructions Electrical Do not operate equipment with a damaged cord or equipment that has be...

Page 3: ...r Do not place any tools weights or other objects on the safety hood while operating the balancer Verify that the wheel is mounted properly and that the wing nut is firmly tightened before spinning the wheel The safety hood must be closed before touching the green START button to spin the wheel Raise safety hood only after wheel has come to a complete stop If safety hood is raised before the spin ...

Page 4: ...e of wheel assemblies The laser is not a field serviceable part No maintenance is to be performed on the laser Wavelength 650nm 2 8 HammerHead TDC Laser Precaution optional equipment The TDC Top Dead Center Laser Indicator is a class 2M laser designed to aid in applying clip on weights The laser is not a field serviceable or adjustable part Use caution in regard to reflective materials around the ...

Page 5: ...ower the balancer OFF press the O side of the ON OFF switch 2 10 Equipment Specification Table 1 Electrical Voltage 208 240V 3 amp 50 60 Hz 1 ph NEMA 20 amp plug L6 20P Amperage Wattage Table 2 Air Air Pressure Requirements 100 175 psi 7 12 bar Approximate Air Consumption 4 CFM 110 Liters Minute Table 3 Atmospherics Temperature 32 F to 122 F 0 C to 50 C Relative Humidity Up to 95 Non condensing Al...

Page 6: ...ition to slide it on spindle Center wheel on collet and clamp Keep lift under wheel and close hood Lift will automatically lower TIP Allowing the balancer to lower lift will speed up removal 4 2 Remove Wheel From Balancer Place lift under wheel and raise it to wheel Remove wheel clamp Slide lift with wheel on it to end of lift rail Use pedal to lower lift 4 3 Centering Check CenteringCheck is an i...

Page 7: ...s such as diluting agent benzene or corrosive cleaner as they may damage the display ArmorAll wipes are a suitable cleaning product for the touch screen CAUTION Do not touch the screen with chemicals or solvents on fingers i e brake cleaner Doing so will damage the anti glare protector on the screen 5 3 Maintenance Schedule 5 4 End User License Agreement Use of equipment and it s operating softwar...

Page 8: ...two 2 years Normal wear items are not covered with the exception of batteries which are covered for a period of six 6 months Replacement parts purchased through the Hunter Service Center and no longer covered by machine warranty are warranted for a period of six 6 months Warranted parts may be replaced with new or refurbished parts at the discretion of Hunter Engineering Company This warranty does...

Reviews: