6
Step 3-1
Step 3-2 - 3-3
Rubber
Gasket
Rubber
Gasket
Upper
Canopy
Lower
Canopy
Pipe
Decorative
Sleeve
Metal
Gasket
3 • Assembling and Hanging the Fan
Hunter® Fan Company
43113-01 • 05/04/12
Adaptor
WARNING:
Fan may fall if not assembled as directed in these
installation instructions.
Standard Mounting -
9’
ceilings or higher:
• Threading the wires through the adapter, screw the adapter onto
the shaft on the top of the fan and securely tighten the upper
setscrew with the included allen wrench.
• Loosen the lower setscrew in the adapter. Threading the wires
through the 7” pipe, screw the pipe into the adapter on top of the
fan and securely tighten the upper setscrew.
CAUTION:
The adapter has a special coating on the threads. Do
not remove this coating; the coating prevents the downrod from
unscrewing. Once assembled, do not remove the downrod.
• Slide the lower canopy onto the pipe with the large opening
facing the fan.
• Slide the metal gasket and decorative sleeve onto the pipe (in that
order). Orient the gaskets so that the sleeve will overlap the lip of
each gasket.
• Slide the upper canopy onto the pipe with the large opening
facing away from the fan. Then slide the rubber gasket onto the
pipe, oriented so that the lip slides into the sleeve. Continue to
step 3-1.
Low Profile Mounting -
8’ - 9’ ceilings:
Note: For
Low Profile Mounting
, Adapter is not used.
• Threading the wires through the 2.75” pipe, screw the pipe into
the top of the fan and securely tighten the setscrew.
• Slide the lower canopy onto the pipe with the large opening
facing the ceiling, the upper canopy is not used for low profile
mounting.
3-1. Screw the hanger bracket onto the top of the pipe at least three
full turns. Securely tighten the setscrew on the hanger bracket.
3-2. Center the pin in the rubber bushing.
3-3. Holding the fan by both the motor housing and the pipe, lift the
fan assembly and hook both sides of the hanger bracket onto the
bushing pin assembly.