POWERVIEW
®
OPERATION
55
Problem
The louver section is not responding to the PowerView remote.
Solution
IMPORTANT:
A louver section will not operate until it is joined to a group.
Check that the correct group number is selected on the remote.
Check that the batteries in the remote are correctly inserted and
are
fresh. The
LED lights that backlight the remote should come on full bright when
■
STOP is
pressed.
Problem
Couplers are not engaging on coupled panels.
Solution
Check alignment of panels to ensure that the couplers are at equal heights, and
that the gap between panels is not too wide for the couplers to engage. Refer to
panel alignment instructions on page 9.
Problem
The louvers are tilting slowly or do not tilt completely.
Solution
The batteries may be low in the battery wand. Replace the batteries.
Check that the battery wand is securely connected to the power cable, and the
cables are not pinched or caught in the rail.
The louver section may need to be reset. Refer to “Resetting the Louver Section
(If Necessary)” on page 54.
Problem
Louvers do not have full range of motion when performing the louver
function reset.
Solution
Check for external obstructions such as window handles or trim.
Ensure that all louver end caps are fully seated in the louvers.
Try manually operating the louvers. If the louvers can be manually operated
through the full range of motion, the motor will need to be replaced. If the louvers
can not be manually operated through the full range of motion, and there are no
external obstructions, there is an internal issue that will require repair.
Problem
The LED light in the programming button housing signals 8 red blinks.
Solution
This is the low battery indicator. Replace the batteries in the battery wand.