background image

Note

If end limits were already set, the motor will not jog, indicating the motor direction did not change.

Note

Verify that all GROUP lights are turned off on the remote, clear both limits, and try again.

3.2. Check and con

rm

IMPORTANT

Watch out to perform steps 3.2.1 and 3.2.2 immediately after each other to avoid mechanical damage!

Carefully read them 

rst before executing!

3.1.3

Press and release

 the 

stop

 button.

Make sure 

 

no group

 on the remote is

selected.

The blind will jog 2x to indicate it

has reversed motor direction

3.1.4

Release

 the 

manual control button

.

Page 6 of 18

version: 1.0

Summary of Contents for PowerView M40T

Page 1: ...T Factory fresh motors do not have default limits set Limits must be set to enable normal operation If operated without limits the shade could be damaged by rolling over the top or wrapping backwards...

Page 2: ...gn a blind to group 1 1 2 1 Press and hold the manual control button on the motor for 12 seconds The blind will jog 1x at 6 seconds and a second time at 12 seconds 1 2 2 Release the manual control but...

Page 3: ...steps 2 4 and 2 5 within 3 seconds 2 1 Locate the manual control button on your blind 2 2 Press and hold the stop button for 4 seconds Keep pressing until the remote lights start blinking 2 3 Press th...

Page 4: ...6 Release the manual control button 2 7 The blind will jog 2x to indicate it has joined the group 2 8 Press and hold the stop button for 4 seconds The remote will exit programming mode automatically...

Page 5: ...direction has to be checked and reversed if needed If the top or bottom Limit is already set and the motor direction has to be reversed perform a reset before continuing 3 1 Deselect all GROUP number...

Page 6: ...again 3 2 Check and con rm IMPORTANT Watch out to perform steps 3 2 1 and 3 2 2 immediately after each other to avoid mechanical damage Carefully read them rst before executing 3 1 3 Press and releas...

Page 7: ...pen top limit Note It is important to have the fabric of the blind tight around the tube 3 2 1 Press the arrow down button to check motor direction 3 2 2 A If the blind moves upwards repeat steps 3 1...

Page 8: ...and release of the button will toggle between Up Stop and Down 4 1 2 Use the open stop and close buttons to ne tune the blind to the desired position 4 1 3 Press and hold the stop button for 6 second...

Page 9: ...teps 4 1 6 and 4 1 7 within 3 seconds 4 1 4 Press and hold the manual control button 4 1 5 Press the open button The blind will jog 2x to acknowledge the limit is set 4 1 6 Release the manual control...

Page 10: ...tton for 6 seconds The remote will exit programming mode automatically after 20 seconds Keep pressing until the remote lights stop blinking 4 1 8 The top limit is set 4 2 1 Use the manual button on th...

Page 11: ...pen stop and close buttons to ne tune the blind to the desired position 4 2 3 Press and hold the stop button for 6 seconds DO NOT select a group on the remote Keep pressing until the remote lights sta...

Page 12: ...mit is set 4 2 6 Release the manual control button 4 2 7 Press and hold the stop button for 6 seconds The remote will exit programming mode automatically after 20 seconds Keep pressing until the remot...

Page 13: ...t and repeat step 4 2 Close limit bottom 5 Clearing end limits 5 1 Clear top limit IMPORTANT Watch out to perform steps 6 1 2 and 6 1 3 within 3 seconds 5 1 1 Deselect all Group number on the remote 5...

Page 14: ...perform steps 6 2 2 and 6 2 3 within 3 seconds 5 1 3 Press the open button The blind will jog 2x to indicate the top limit is cleared 5 1 4 Release the manual control button 5 2 1 Deselect all Group n...

Page 15: ...position which is set at 50 open by default Setting a new FAVOURITE position overwrites any previous setting 5 2 2 Press and hold the manual control button 5 2 3 Press the close button The blind will...

Page 16: ...n stop close arrow down and the arrow up buttons to move the blind to the desired favourite position 6 1 2 Press and hold the stop button for 6 seconds DO NOT select a group on the remote Keep pressin...

Page 17: ...e motor direction is reset The default FAVORITE position will be at 50 after limits are set 6 1 4 Press the heart button The blind will jog 2x to indicate the favourite position is set 6 1 5 Release t...

Page 18: ...7 2 Release the manual control button after the third jog The Network ID Group assignments and end Limits have been cleared Page 18 of 18 version 1 0...