2. Remove the lower panel (B): to do this, unscrew clamping screws (C);
3. Clean the condenser fins (D);
4. After cleaning, reinstall and screw the panel.
5.
TROUBLESHOOTING
The information given below is intended to facilitate the identification and elimination of
malfunctions that may occur during the use of the device. Certain malfunctions can be
eliminated by user’s own forces. To eliminate other malfunctions, please contact a
specialized service center.
Malfunction
Cause
Remedy
The
device
is
not
enabled
No power
Check the power supply cable
Check the fuses
Check that the device is
properly connected
Other
Contact the service center
The
device
is
functioning, but cooling
is insufficient
Too high room temperature Ventilate the room
The
condenser
is
contaminated
Clean the condenser
The chamber door is not
closed tightly
Check the door seal
Insufficient
refrigerant
volume
Contact the service center
The condenser fan has
stopped
Contact the service center
The evaporator fan has
stopped
Contact the service center
The cooling system is
not switched off
Faulty thermal probe
Contact the service center
Faulty control board
Contact the service center
Ice in the evaporator
Carry out the defrosting cycle
If
the
problem
persists,
contact the service center
Intense noise during
device operation
Sustained vibration
Check whether the device
contacts foreign objects (both
outside and inside)
6.
INSTALLATION
6.1.
Packaging
Carry out transportation and packaging of the device relying only on the information
specified on the packaging, on the device itself and in this manual.
Packaging is made of cardboard and plywood. Packaging contains special signs that regulate
handling, transportation and storage in accordance with international standards.