56
➢
when the temperature of the thermal probe reaches the set value,
- the device switches to the storage mode;
-
icon flashes, and
indicator lights up;
- the information on the “End” of the cycle is displayed;
- the device provides the sound alarm;
- press any button to stop the sound alarm, press again to remove the “End” message.
During storage:
➢
the chamber temperature is displayed;
➢
If the cooling was completed successfully,
and
indicators light up; if
the cooling required additional time,
and
indicators light up, and
icon flashes;
➢
press
several times:
- to display
nEg
message;
- to exit the mode (or leave for 15 sec for the device exiting the mode independently).
To stop the cycle:
➢
press and hold
button for 2 sec.
10.3.
HKN-BCF3, HKN-BCF5, HKN-BCF10, HKN-BCF14 control panel
display
Dixell XB590L master controller is used in HKN-BCF3, HKN-BCF5, HKN-BCF10, HKN-
BCF14 models.
The controller has the following features:
➢
possibility to stop any cooling/freezing cycle;
➢
possibility to use in each cycle up to 3 thermal probes or the thermal probe with 3
temperature sensors;
➢
defrosting during cycles is prevented, the fans are always running. The defrosting
cycle can be started before any cooling/freezing cycle;
➢
each cycle can be separated into 3 phases in compliance with the set parameters;
➢
the sound alarm warns of too low or too high temperature of the condenser;
➢
keeping the log of the last 15 accidents (high temperature, power failure and excess
of maximum cycle time);
➢
each device has the display connection;