TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION

MOTOR RUNS, BUT THE 

TOOL JAWS WILL NOT 

ADVANCE

Insufficient Hydraulic Oil

Consult Factory for Repair 
Service

Air Block in Hydraulic System

Invert tool to allow air to rise 
towards the top of the oil 
bladder

Defective Hydraulic Circuit

Consult Factory for Repair 
Service

MOTOR RUNS, TOOL JAWS 

ADVANCE, BUT WILL NOT 

BUILD PRESSURE

Insufficient Hydraulic Oil

Consult Factory for Repair 
Service

Defective Suction Valve or 
Bypass Cartridge

Consult Factory for Repair 
Service

MOTOR WILL NOT RUN AT 

ALL

Defective Battery

Charge or Replace Battery

Bad Contact or Loose Battery 
Connections

Check all Connections and 
Wires

Misaligned Switch

Check to Make Sure that 
Switch is Properly Aligned with 
Trigger
Consult Factory for Repair 
Service

TOOL JAWS WILL NOT 

RELEASE

Tool Did Not Complete a Full 
Cycle and Bypass

Press Trigger and allow Tool 
to Bypass, Then Release Tool 
Jaws

Connector is Jammed in Tool 
Jaws

Press and Hold Release Trigger 
While Prying Tool Jaws Apart

Release Trigger is Bent or Mis-
aligned

Consult Factory for Repair 
Service

Summary of Contents for ECO-336

Page 1: ...Streamline Cutting Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139 Pho...

Page 2: ...resent state of the art tools and be dependable and safe All products will carry an unconditional guarantee to be free from defects and to perform as advertised Please take the time to read this manua...

Page 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Page 4: ...ye protection when operating this tool Failure to wear eye protection could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using th...

Page 5: ...rger can charge the BP 84 BP 82 and BP 80 only Huskie Tools batteries including the BP 70 BP 70EI and the BP 70MH must be charged with the CH 90 CH 80 or previous charger models The ECO 336 streamline...

Page 6: ...rd Guy Wire 3 8 Features Lightweight ergonomic design One handed operation Rotational Head Tested up to 75kV Compatible with all Huskie 14 4V Batteries 1 Year Warranty The ECO 336 streamline battery p...

Page 7: ...lashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occur...

Page 8: ...800 860 6170 RIGHT WRONG CUTTING 1 Retract blades by pressing the release button 2 Be sure that material being cut is within the specified cutting capacity of the tool 3 Place the material to be cut b...

Page 9: ...cartridges to cool before charging Allow at least 15 minutes between charges when charging several cartridges in succession 4 Charge batteries at an ambient temperature of 50 95 F 10 35 C Charging tim...

Page 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN...

Page 11: ...9 1 45 P28 O Ring EZ 29 1 14 S 32 O Ring EZ 10 1 46 P28 Back Up Ring 55D 03 1 15 Oil Reservoir EZ 11 1 47 Ram 336 47 1 16 S 36 O Ring EZ 12 1 48 Ram Spring 336 48 1 17 Bush R14A 19 1 49 Cover 336 49 1...

Page 12: ...Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connect...

Page 13: ...www spartacogroup com 800 860 6170 13 NOTES...

Page 14: ...www spartacogroup com 800 860 6170 14 NOTES...

Page 15: ...www spartacogroup com 800 860 6170 15 NOTES...

Page 16: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Reviews: