OPERATING INSTRUCTIONS 

CUTTING 

1. Operate the switch (forward or reverse) by depressing the 

  center lock-out button and toggle the switch up or down to 

  release the movable blade.

2. Place the cable to be cut onto the stationary blade and rotate  

  the moveable blade around the cable by hand and engage into  

  the drive gear.

3. While holding the center lock-out button, depress the forward  

  toggle switch to drive the blade through the cable to be cut.  

  Hold switch until cable is completely cut.

4. To cut continuous on smaller diameter cable, rotate the toggle  

  switch forward and reverse with the blade engaged in the drive  

 gear.

5. When completed, remove any chips that may have become 

  attached to the brush during use. This will help avoid damage to  

  the drive gear.

CIRCUIT BREAKER 

1. The circuit breaker will be activated, and the tool stops, in the    

following circumstances:

•   Oversized or harder material is cut.

•   The tool becomes overheated from successive use.

•   Drawn Amperage exceeds the rated amperage.

•   (The reset pin will pop out about 2mm from its original position.)
2. To continue using the tool, wait 10 seconds to 1 minute and press

  the reset pin back into position. (Normal operation can resume    

  when the reset pin has been returned to its original position)

 

Note:

 The circuit breaker may also be activated even operating

  the tool within the cutting capacity. The operating temperature,

  cable bend and other factors affect the performance of the tool.

Summary of Contents for REC-5OU

Page 1: ...OPERATING INSTRUCTION MANUAL REC 5OU GEAR DRIVEN BATTERY POWERED CUTTING TOOL 2 JAW OPENING...

Page 2: ...www huskietools com 2 huskietoolsinc linkedin com company huskie tools youtube com user huskietools facebook com huskietools Connect with us...

Page 3: ...on Tested up to 75kV Ergonomically Balanced Weather Resistant Housing Overload Circuit Breaker Protection For Copper and Aluminum Only 5 Year Warranty on Tool Battery Charger BATTERY CARTRIDGE BP 80 B...

Page 4: ...90 Huskie Tools Tri Chemistry Charger This charger can charge the BP 80 and ALL previous Huskie Tools batteries including the BP 70 BP 70EI and the BP 70MH 1 Battery Powered Tool 1 Carrying Case 1 CH...

Page 5: ...goes out or is flashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a...

Page 6: ...e drive gear 5 When completed remove any chips that may have become attached to the brush during use This will help avoid damage to the drive gear CIRCUIT BREAKER 1 The circuit breaker will be activat...

Page 7: ...ping capacity becomes about 1 2 that of the original capacity the battery should be replaced 6 If the battery cartridge is stored without being charged natural drainage will cause the power to be redu...

Page 8: ...www huskietools com 8 REC 50U BREAKDOWN...

Page 9: ...RC50 15 1 16 Moving Blade RC50 16 1 17 Needle Pin RC50 17 2 18 Stationary Blade RC50 18 1 19 Gear Case Ass y RC50 19 1 20 M4 X 8 Screw RC50 20 2 21 Gear RC50 21 1 22 Gear Plate RC50 22 2 23 Gear Cover...

Page 10: ...www huskietools com 10...

Page 11: ...RE DISCLAIMED Huskie reserves the right to determine all warranty claims Huskie will not warranty tools containing parts or batteries not originally supplied by Huskie Failure due to misuse improper m...

Page 12: ...s purchase date and problem You will be given a RGA to assure that your merchandise will be properly handled upon its receipt 2 CAUTION Make sure the product is packaged adequately so as to prevent d...

Page 13: ......

Page 14: ...198 N Brandon Drive Glendale Heights Illinois 60139 Toll Free 1 800 860 6170 Fax 800 345 3767 huskietools com info huskietools com 6 12...

Reviews: