OPERATING PRECAUTIONS

 PRECAUTION FOR THE TOOL

  PRECAUTION FOR THE CHARGER

1. Always point the tool 

AWAY 

from other people.

2. If the tool is stored for an extended period at a temperature of less than 25º F (-5ºC), the tool 

should be allowed to return to room temperature to ensure smooth operation Use the tool only 

after it has been at room temperature for 1 hour.

3. Do not drop the tool. Dropping the tool may damage the hydraulic circuit and result in the tool 

not functioning correctly.

4. Keep the head and ram clean and free of debris. Solvents can be used to clean the head, but  

should not be used on the plastic body. Use soap and water to clean the body. 

5. Do not use tool for continous use. If any sign of over heating, allow the tool to cool for 15 mins.

6. Do not allow tool to be submerged in water. The tool may be used to in damp or wet

 environments. However it is recommended for tool to be air-dried before use.

 PRECAUTION FOR THE BATTERY CARTRIDGE

1. Do not short circuit the contacts or expose the cartridge to water, oil or solvents.

2. Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire.

3. Do not drop or otherwise abuse the battery cartridge.

4. Do not leave the cartridge in locations where it will be exposed to a temperature greater than 

140ºF  (60ºC) for an extended period.

5. The battery has a limited life. When the crimping capacity becomes about 1/2 that of the 

original capacity, the battery should be replaced.

6. If the battery cartridge is stored without being charged, natural drainage will cause the power 

to be  reduced. The battery should be charged every 3 months if not in use.

1.  The LED indicator lights up amber and remains lit when the unit starts charging a battery 

cartridge. The indicator turns green when charging is completed.

2.  The BP-84 can be charged with any of the Huskie Lithium-Ion chargers including the CH-80, 

CH-90 & CH-94. 

3.  Allow battery cartridges to cool before charging. Allow at least 15 minutes between charges 

when charging several cartridges in succession.

4.  Charge batteries at an ambient temperature of 50º-95ºF (10º-35º C). Charging time is 

approximately 50-70 minutes for the BP-84. 

5.  Never short circuit the output terminals.

6.  Do not expose the charger to water, oil or solvents.

7.  Do not disassemble, attempt to modify, drop or otherwise abuse charger.

Summary of Contents for SL-S20

Page 1: ...Streamline Cutting Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139 Phon...

Page 2: ...products represents the state of the art tools and are dependable safe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie Tools Please take the time...

Page 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Page 4: ...ye protection when operating this tool Failure to wear eye protec tion could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using t...

Page 5: ...0EI and the BP 70MH must be charged with the CH 90 CH 80 or previous charger models The SL S20 was designed to cut the toughest materials used in construction today It can replace an entire tool kit i...

Page 6: ...36 ACSR 90 1 2 Wire Rope 90 1 2 Rebar 60 1 2 Ground Rod 60 3 8 Guy Wire 45 Cutting Capabilities Wire Rope 5 8 Rebar Sc 40 1 2 Rebar Sc 60 3 8 Ground Rod 1 2 ACSR 477 MCM Guy Wire 3 8 Features Flip Top...

Page 7: ...lashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occur...

Page 8: ...it may be difficult to retract blades If this occurs continue to advance tool and build pressure A series of clicks will be heard while the tool running in a neutral mode This indicates that the tool...

Page 9: ...o not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not drop or otherwise abuse the battery cartridge 4 Do not leave the cartridge in locations where it will be e...

Page 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN __ I I I I I I...

Page 11: ...62 Head Shear 20 02 1 16 S 32 O Ring EZ 10 1 63 Shoulder Bolt 16 03B 4 17 Plug SLND 12 1 64 M6 Lock Washer 16 02 4 18 Oil Reservoir 44 SLND 13 1 65 M6 Hex Nut 16 01 4 19 S 36 O Ring EZ 12 1 20 Bush R1...

Page 12: ...Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connect...

Page 13: ...NOTES...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Reviews: