Safety Information (continued) 

 

AIR COMPRESSOR AND PNEUMATIC TOOL 

SAFETY 

 

WARNING: 

Do not attempt to modify this tool or create 

accessories not recommended for use with this tool. Any 
such alteration or modification is misuse and could result in 
a hazardous condition leading to possible serious personal 
injury.

 

 

CAUTION: 

Do not use in an environment that is dusty or 

otherwise contaminated. Using the air compressor in this 
type of environment may cause damage to the unit.

1.

Keep compressors as far from the spraying area as possible, 
at least 15 ft. from the spraying area and all explosive 
vapors. 

2.

Risk of bursting. Do not adjust the regulator to result in 
output pressure greater than the marked maximum pressure 
of the attachment. Do not use at pressure greater than the 
rated maximum pressure of this compressor. 

3.

If connected to a circuit protected by fuses, use time-delay 
fuses with this product. 

4.

To reduce the risk of electric shock, do not expose to rain. 
Store indoors. 

5.

Ensure the hose is free of obstructions or snags. Entangled 
or snarled hoses can cause loss 

of 

balance or footing and 

may become damaged. 

6.

Use the air compressor only for its intended use. Do not alter 
or modify the unit from the original design or function. Never 
weld or drill holes in the air tank. 

7.

Never leave a tool unattended with the air hose attached. 

8.

Do not operate this tool if it does not contain a legible 
warning label. 

9.

Do not continue to use a tool or hose that leaks air or does 
not function properly. 

10. Do not attempt to pull or carry the air compressor by the 

hose. 

11. Your tool may require more air consumption than this air 

compressor is capable 

of 

providing. 

12. Never direct a jet of compressed air toward people or 

animals. 

13. Protect your lungs. Wear a face or dust mask if the operation 

is dusty. 

14. Do not use this air compressor to spray chemicals. Your 

lungs can be damaged by inhaling toxic fumes. A respirator 
may be necessary in dusty environments or when spraying 
paint.  

15. Do not use this compressor if any parts have been exposed 

to water. 

ELECTRICAL SAFETY 

1.

Avoid body contact with grounded surfaces such as pipes, 

radiators, ranges, and refrigerators. There is an increased 

risk of electric shock if your body is grounded. 

2.

Do not expose power tools to rain or wet conditions. Water 

entering a power tool will increase the risk of electric shock. 

3.

Do not abuse the cord. Never use the cord to carry the tool 

or pull the plug from an outlet. Keep the cord away from 

heat, oil, sharp edges, and moving parts. 

4.

Replace damaged cords immediately. Damaged cords 

increase the risk of electric shock. 

ELECTRICAL SAFETY (EXTENSION CORDS) 

WARNING: 

Keep the extension cord clear of the working 

area. Position the cord so that it will not get caught on 
lumber, tools, or other obstructions while you are working 
with a power tool. Failure to do so can result in serious 
personal injury.

 

WARNING: 

Check extension cords before each use. If 

damaged, replace immediately. Never use the air 
compressor with a damaged cord since touching the 
damaged area could cause electrical shock resulting in 
serious personal injury.

 

WARNING: 

Improperly connecting the equipment· 

grounding conductor can result in a risk of electrical shock.

 

1.

Use only 3-wire extension cords that have 3-prong 

grounding plugs and 3-pole receptacles that accept the air 

compressor's plug. 

2.

When using the air compressor at a considerable distance 

from the power source, use an extension cord heavy enough 

to carry the current that the compressor will draw. An 

undersized extension cord will cause a drop in line voltage, 

resulting in a loss of power and causing the motor to 

overheat. Use the following chart to determine the minimum 

wire size required in an extension cord. 

3.

Only use 50 ft. or less round jacketed cords listed by 

Underwriter's Laboratories (UL). 

4.

When operating a power tool outside, use an outdoor 

extension cord marked “w-A” or “w”. These cords are rated 

for outdoor use and reduce the risk of electric shock. 

 

 

Summary of Contents for 0300813A

Page 1: ...ducts designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 8 GALLON HOTDOG OIL FREE...

Page 2: ...is necessary to properly lter and purify the air to meet minimal speci cations for Grade D breathing as described in Compressed Gas Association Commodity Speci cation G 7 1 1966 OSHA 29 CF9 1910 134 C...

Page 3: ...ressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint 15 Do not use this compressor if any parts have b...

Page 4: ...heavy enough for a short distance will be too light for a greater distance A line that can support one power tool may not be able to support two or three tools ELECTRICAL SAFETY GROUNDING INSTRUCTIONS...

Page 5: ...han those specifically stated in this warranty ADDITIONAL LIMITATIONS To the extent permitted by applicable law all implied warranties including warranties of merchantability or fitness for a particul...

Page 6: ...ndle F 2 Thumbscrews C 25 coil air hose quick coupler female quick plug male quick plugs 2 blow gun tire chuck high pressure nozzle inflation needles 2 adaptor sealant tape Instruction manual TOOLS RE...

Page 7: ...mbscrews C 2 Rubber foot D 1 k n a T E 1 1 1 1 1 Handle F G Pressure regulator knob H Quick coupler I Regulator pressure gauge 1 Tank pressure gauge J 1 Safety valve K h c t i w S F F O N O L 1 Air lt...

Page 8: ...mble a M10 shoulder bolt AA through the holes in the wheel and tank wheel bracket Place a at washer DD lock washer CC onto the threaded end of the shoulder bolt AA Then place a M10 nut BB on the threa...

Page 9: ...regulator G clockwise until desired pressure is reached The compressor is ready for use How to shut down Set the ON OFF switch I to the O off position Unplug the power cord X Reduce the pressure in th...

Page 10: ...Ball valve Ball valve Ball valve Ball valve Ball valve Ball valve Maintenance 10...

Page 11: ...N connect it directly to the air hose U pre attached If using the inflation needle 0 pre attached connect it directly to the blow gun N If using the high pressure nozzle Q connect it directly to the b...

Page 12: ...requirement of the accessory If it is higher than the CFM and the pressure supplied bythe compressor you need a larger compressor Most accessories are rated at 25 of the actual CFM while running conti...

Page 13: ...3 1 Service Parts EXPLODED VIEW M O C S L O O T Y K S U H e c n a t s i s s a r e h t r u f r o f Y K S U H D H 8 8 8 1 t c a t n o c e s a e l P...

Page 14: ...ut 6 7 Power cord 1 1 1 8 Check valve 9 Thumbscrew Quick coupler 0 1 Regulator assy 1 1 12 Handle 13 Handgrip 14 Safety valve 1 2 15 Pressure gauge e l u r r e f h c t i w S 6 1 ON OFF switch 7 1 18 F...

Page 15: ...ions problems missing parts Before returning to the store call Husky Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 888 HD HUSKY HUSKYTOOLS COM Retain this manual for future...

Page 16: ...n Visitez nous en ligne pour voir notre gamme compl te de produits disponibles pour vos besoins de r novation Merci d avoir choisi Husky GUIDE D UTILISATION ET D ENTRETIEN COMPRESSEUR D AIR HOT DOG 8...

Page 17: ...as especi caciones m nimas para respiraci n Grado D como se describe en Especi caciones para Art culos de la Asociaci n de Gas comprimido G 7 1 1966 OSHA 29 CF9 1910 134 Compressed Gas Association 422...

Page 18: ...den resultar da ados al inhalar humos t xicos Puede ser necesario un respirador en ambientes de mucho polvo o cuando roc e pintura 15 No use este compresor si alguna parte ha estado expuesta al agua S...

Page 19: ...n cable su cientemente fuerte para una distancia corta ser muy ligero para una distancia mayor Una l nea que puede soportar una herramienta el ctrica puede no ser capaz de soportar dos o tres herramie...

Page 20: ...ficamente en esta garant a LIMITACIONES ADICIONALES En la medida permitida por la ley aplicable todas las garant as impl citas incluyendo garant as de comercializaci n o idoneidad para un prop sito p...

Page 21: ...pidos macho 2 pistola de aire comprimido la tirada de los neum ticos la boquilla de alta presi n agujas de in aci n 2 adaptador cinta selladora Manual de instrucciones samblaje de la manija incluye 1...

Page 22: ...i n H o d i p r r o d a l p o c A I r o d a l u g e r o r t e m n a M J e u q n a t l e d o r t e m n a M K d a d i r u g e s e d a l u v l V L M F Interruptor de Encendido Apagado Cantidad 2 1 2 2 1...

Page 23: ...no de resalto de M10 AA a trav s de los agujeros en la rueda y el soporte de la rueda del tanque Coloque una arandelas planas dd arandela CC en el extremo roscado del tornillo de hombro AA Luego coloq...

Page 24: ...oj hasta que se alcance la presi n deseada El compresor est listo para usarse C MO DESCONECTARLA Coloque el interruptor de ENCENDIDO APAGADO I en la posici n O apagado Desenchufe el cable el ctrico X...

Page 25: ...10 Mantenimiento...

Page 26: ...R R H 11 Asamblea continuaci n Si se utiliza un mandril neum tico S conectarlo a un enchufe r pido macho W y luego conectar con el acoplamiento r pido V R w...

Page 27: ...istrada por el compresor necesitar un compresor m s grande La mayor a de los accesorios est n clasi cados para el 25 de los m3 min reales que se utilizan durante el funcionamiento continuo La v lvula...

Page 28: ...3 1 Piezas de servicio VISTA ESQUEM TICA M O C S L O O T Y K S U H l a n o i c i d a a i c n e t s i s a a r a p Y K S U H D H 8 8 8 1 l e n o c o t c a t n o c n e e s a g n P...

Page 29: ...alimentaci n 1 1 1 8 V lvula de retenci n 9 Tornillo de mariposa Acoplador r pido 0 1 Regulador 1 1 12 Manija 13 Agarre de la manija 14 V lvula de drenaje 1 2 15 Man metro a l o r i V 6 1 Interruptor...

Page 30: ...iezas Antes de regresar a la tienda llame a Servicio al Cliente de Husky de 8 a m a 7 p m hora local del Este de lunes a viernes 9 a m a 6 p m hora local del Este s bado 1 888 HD HUSKY HUSKYTOOLS COM...

Reviews: