18
Maintenance (continued)
CHANGING THE OIL
When changing the pump oil, be sure to do the
following:
□
Turn the unit off and unplug the power cord from
the receptacle.
□
Allow the compressor time to cool if it has been
in operation.
□
Open the drain valve (3) to bleed all the air from
the tank.
□
Close the drain valve (3).
□
Remove the oil fill cap (1) on the pump.
□
Remove the sight glass (2) with a box-end
wrench or socket. Drain the oil into a suitable
container and dispose of properly. The
compressor may need to be tipped slightly
towards the drain hole to allow all of the oil to
drain.
□
Reattach the sight glass (2). Torque the sight
glass 10-12 inch lbs. when re-assembling. Be
sure the gasket is between the sight glass and
the pump crankcase.
□
Refill the compressor pump with an air
compressor oil, such as SAE-30 non-detergent,
Semi Synthetic oil, at slow intervals until the oil
reaches the center of the red circle in the sight
glass (2). Use a SAE-10 during extreme winter
conditions.
3
1
2
Care and Cleaning
□
Drain the air tank of moisture after operation.
□
When not in use, store the compressor in a cool, dry place.
□
Disconnect the air hose and hang open ends down to allow any moisture to drain.
□
Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them
loosely around the compressor handle.