LIMITED TWO-YEAR WARRANTY

WHAT IS COVERED

From the date of purchase, parts and labor are covered to remedy substantial defects due to material and workmanship during the fi rst year of ownership 
with the exceptions noted below. From the date of purchase, parts only are covered to remedy substantial defects due to material and workmanship during 
the second year of coverage with exceptions noted below.

This warranty applies only to the original retail purchaser and may not be transferred. If the compressor is used for commercial, industrial, or rental 
purposes, the warranty will apply for ninety (90) days from the date of purchase. Two-stage compressors are not limited to a ninety (90) day warranty when 
used in commercial or industrial applications. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not 
apply to you.

WARRANTOR: Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030 Telephone: (800) 543-6400

The responsibilities of the warrantor under this warranty is to repair or replace, at the warrantor’s option, this compressor or components which are 
defective, have malfunctioned, and/or have failed to conform within the duration of the specific warranty period. Repair or replacement will be scheduled 
and serviced according to the normal work-flow at the servicing location and will depend on the availability of replacement parts.

The responsibilities of the purchaser under this warranty are as follows: a) provide dated proof of purchase and maintenance records; b) call to obtain 
your warranty service options [freight costs must be borne by the purchaser]; c) use reasonable care in the operation and maintenance of the products 
as described in the owner’s manual(s); d) repairs requiring overtime, weekend rates, or anything beyond the standard manufacturer warranty repair labor 
reimbursement rate; e) time required for any security checks, safety training, or similar for service personnel to gain access to facility; and f) location of 
unit must have adequate clearance for service personnel to perform repairs and easily accessible.

WHAT IS NOT COVERED

This warranty does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modifi cation, or 
repair by other than a service center authorized by the manufacturer to repair this air compressor. Expendable materials, such as motor brushes, seals, etc. 
are not covered by this warranty. This warranty does not apply to this compressor used in industrial applications or for rental purposes. Husky makes no 
warranties, representations, or promises as to the quality or performance of its air compressors other than those specifi cally stated in this warranty.

Implied warranties, including those of merchantability and fi tness for a particular purpose, are limited to two years from the date of original purchase 
by the consumer.

 Any incidental, indirect, or consequential loss, damage, or expense that may result from any defect, failure, or malfunction of the 

manufacturer’s product is not covered by this warranty. Some states do not allow the exclusion or limitations of incidental or consequential damages, so 
the above limitation or exclusion may not apply to you. The warranty does not cover any failure that results from an accident, purchaser’s abuse, neglect, or 
failure to operate products in accordance with instructions provided in the owner’s manual(s) supplied with compressor.

This warranty does not cover pre-delivery service, i.e. assembly, oil or lubricants, and adjustment. This warranty does not cover items or service that is 
normally required to maintain the product, i.e. lubricants, fi lters, gaskets, etc.

Gasoline engines and components are expressly excluded from coverage under this limited warranty. The purchaser must comply with the warranty given 
by the engine manufacturer which is supplied with the product.

The following items not covered under this warranty. This warranty excludes these items (pertaining to all compressors) as follows: a) any component 
damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines 
or damaged by contact with tools or surroundings; b) pump or valve failure caused by rain, excessive humidity, corrosive environments, or other 
contaminants; c) cosmetic defects that do not interfere with compressor functionality; d) rusted tanks, including but not limited to rust due to improper 
drainage or corrosive environments; e) any components that are considered normal wear items and are not covered after the fi rst year of ownership [the 
electric motor, check valve, pressure switch, regulator, pressure gauges, hose, tubing, pipe, fi ttings and couplers, screws, nuts, hardware items, belts, 
pulleys, fl ywheel, air fi lter and housing, gaskets, seals, oil leaks, air leaks, oil consumption or usage, piston rings]; f) the tank drain valves; g) damage 
due to incorrect voltage or improper wiring; h) other items not listed but considered general wear parts; i) pressure switches, air governors, load/unload 
devices, throttle control devices, and safety valves modifi ed from factory settings; j) damage from inadequate fi lter maintenance; and k) induction motors 
operated with electricity produced by a generator.

The following items not covered under this warranty. This warranty excludes these items (specifi c to lubricated compressors) as follows: a) pump wear or 
valve damage caused by using oil not specifi ed; b) pump wear or damage caused by any oil contamination; and c) pump wear or damage caused by failure 
to follow proper oil maintenance guidelines, operation below proper oil level, or operation without oil.

Labor, service calls, or transportation charges after the fi rst year of ownership are not covered on stationary air compressors. Stationary air compressors 
are defi ned as those units not including a handle or wheels.

This Limited Warranty applies in the U.S., Canada, and Mexico only This warranty gives you specifi c legal rights, and you may also have other rights which 
vary from state to state.

How to get service: Call 1-888-43-HUSKY or visit www.HUSKYTOOLS.com.

Summary of Contents for 1000710098

Page 1: ...enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 60 GALLON STATIONARY AIR COMPRESSOR Questi...

Page 2: ...ntly hazardous situation which if not avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CA...

Page 3: ...he tank resulting in damage from rupture or explosion Always replace worn cracked or damaged tanks CAUTION See the compressor specification decal for maximum operating pressure Do not operate with pre...

Page 4: ...not recommended for use with this compressor Alterations and or modifications are a form of misuse which could result in a hazardous condition leading to possible personal injury or equipment damage...

Page 5: ...l and local electrical codes 1 Follow all local electrical and safety codes as well as in the United States the National Electrical Codes NEC and Occupational Safety and Health Act OSHA 2 Avoid body c...

Page 6: ...or expense that may result from any defect failure or malfunction of the manufacturer s product is not covered by this warranty Some states do not allow the exclusion or limitations of incidental or...

Page 7: ...a minimum clearance of 18 in between the compressor flywheel or fan and the wall and ensure clear access to the drain valve to facilitate condensate drainage Do not locate the compressor air inlet ne...

Page 8: ...8 Pre Installation PACKAGE CONTENTS Part Description Quantity A Air Compressor Unit 1 B Air Filter Assembly 1 A B...

Page 9: ...sure from the discharge tube and allows the compressor to restart easier B ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum C Discharge Tube This...

Page 10: ...tlet Size 3 4 NPT Number of Cylinders 2 Oil Capacity approximately 8 5 ounces Voltage 230 240 Volts 15 Amps Length 20 in 60 Hz 1 Phase Width 20 in Air Delivery 90 psi 10 2 SCFM Height 66 5 in Air Deli...

Page 11: ...s to the drain valve to facilitate condensate drainage IMPORTANT It is extremely important to install the compressor in a clean well ventilated area where the surrounding air temperature will not be m...

Page 12: ...onry bit Holes drilled must be at least as deep as the concrete wedge anchors being used 3 Inserting the mounting bolts Insert the mounting bolts into the drilled holes Place a washer on each bolt Thr...

Page 13: ...outlet For units that do not have a factory installed cord install permanent wiring from the electrical source to the pressure switch with a ground conductor connected to the grounding screw on the pr...

Page 14: ...l 2 line terminal 3 ground screw 4 and ground line 5 3 Making the electrical connections Remove the ground screw 1 Install the strain relief on the pressure switch 2 Do not tighten the strain relief o...

Page 15: ...screwdriver with a hammer until tight Tighten the strain relief screws 2 to hold the power cord securely 5 Reinstalling the pressure switch cover Replace the pressure switch cover The knob must be in...

Page 16: ...ife of the unit you will clean or replace the filter as needed This air compressor unit can be installed as part of an air distribution system Any tube pipe or hose used in an air distribution system...

Page 17: ...n the pump to determine the oil level Add oil to the pump if the oil level is low 2 2 Starting up and breaking in the compressor WARNING Do not attach air tools to the open end of the hose until start...

Page 18: ...0 50 psi Do not operate the drain with more than 40 psi in the tank or the drain valve may be damaged Drain the tank of moisture daily using the drain valve at the bottom of the tank IMPORTANT This co...

Page 19: ...insert the oil drain plug Remove the breather 3 from the pump Pour new unused oil into the pump Do not overfill Reinsert the breather 3 into position Return power to the compressor for use 2 Checking...

Page 20: ...do not remove the four bolts 1 holding the motor in place Shift the motor towards the pump The belt should be slack and easily removed Replace the belt Move the motor back to the original position to...

Page 21: ...all service relocate or perform any maintenance Operation Daily Weekly Monthly Every 3 Months Check Oil Level X Drain Tank X Check Air Filter X Check Safety Valve X Clean Unit X Check Belt Tension X C...

Page 22: ...l more frequently The piston pin bores are worn Remove the piston assemblies from the compressor and inspect for excess wear Replace the excessively worn piston pin or pistons as required Maintain the...

Page 23: ...is restricted Clean or replace the air filter element The electrical connections are loose Check all the electrical connections The pressure switch shut off pressure is set too high Replace the pressu...

Page 24: ...24 Service Parts Compressor MODEL VT631404 3 4 27 28 25 29 32 33 31 30 26 34 21 22 2 7 11 12 5 10 19 17 23 24...

Page 25: ...ting ST081301AV 1 20 Unloader tube ST117802AV 1 21 Pump VT472200AJ 1 22 Oil drain plug ST022300AV 1 23 Compression assembly ST018300AV 1 24 Self tapping screw ST016500AV 4 25 Belt BT013001AV 1 26 Flyw...

Page 26: ...26 Service Parts Pump MODEL VT472200AJ 18 17 15 14 12 13 19 20 21 22 24 23 25 26 27 28 1 2 3 2 4 5 6 7 8 9 10 11 16...

Page 27: ...rew 4 15 Flange head screw 2 16 Washer 2 17 Air filter assembly VH901700AV 1 18 Air filter element VH901800AV 1 19 Pump head 1 20 Valve plate gasket 1 21 O ring VT036700AV 1 22 Valve plate 1 23 Cylind...

Page 28: ...s problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use Document Number IN63960...