background image

WARNING: Risk of Bursting

Air Tank: The following conditions could lead to a weakening of the tank, and result
in a violent tank explosion and could cause property damage or serious injury.

How To Prevent It

What Could Happen

WARNING: Risk from Flying Objects

HOW TO PREVENT IT

WHAT CAN HAPPEN

The compressed air stream can cause
soft tissue damage 
to exposed skin and
can propel 
dirt, chips, loose particles,
and small objects at high speed,
resulting in property damage or personal
injury.

Always wear ANSI Z87.1 approved
safety glasses with side shields 
when
using the compressor.

Never point any nozzle or sprayer
toward 
any part of the body or at other
people or animals.

Always turn the compressor off and
bleed pressure 
from the air hose and
tank before attempting maintenance,
attaching tools or accessories.

HAZARD

HAZARD

Drain tank daily or after each use. If
tank develops a leak, replace it
immediately with a new tank or replace
the entire compressor.

1.

Failure to properly drain
condensed water from tank,
causing rust and thinning of the
steel tank.

2. 

Modifications or attempted repairs
to the tank.

3.

Unauthorized modifications to the
unloader valve, safety valve, or any
other components which control
tank pressure.

Never drill into, weld, or make any
modifications to the tank 
or its
attachments.

4.

Excessive vibration can weaken
the air tank and cause rupture or
explosion

The tank is designed to withstand specific
operating pressures. Never make
adjustments or parts substitutions to
alter the factory set operating
pressures.

For essential control of air pressure, you
must install a pressure regulator and
pressure gauge to the air outlet (if not
equipped) 
of your compressor. Follow the
equipment manufacturers
recommendation and never exceed the
maximum allowable pressure rating of
attachments. Never use compressor to
inflate small low pressure objects such
as children’s toys, footballs,
basketballs, etc.

ATTACHMENTS  & ACCESSORIES:

Exceeding the pressure rating of air
tools, 
spray guns, air operated
accessories, tires, and other inflatables
can cause them to explode or fly apart,
and could result in serious injury.

5

Summary of Contents for 41214

Page 1: ...1 5 GALLON OIL FREE AIR COMPRESSOR FOR SAFE OPERATION READ AND UNDERSTAND ALL CONTENTS OF THE INSTRUCTION MANUAL Model 41214 1 TOLL FREE HELPLINE 1 877 888 3872 ...

Page 2: ... 41214 Motor 120V 60Hz 8 amp Watts 960 watts Tank Size 1 5 gallon Pump Type Single Cylinder Belt Drive Air Hose Type 25 Recoil MAX 200 PSI Air Delivery 3 0 SCFM 40 PSI 2 0 SCFM 90 PSI Cut in Pressure 100 PSI Cut out Pressure 135 PSI Max Pressure 135 PSI Power Cord 6ft 3 prong 18 AWG Weight 31 5lbs 14 3kg 2 2 3 9 10 11 15 17 22 25 27 30 TABLE OF CONTENTS SPECIFICATIONS ...

Page 3: ...nd pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products ...

Page 4: ...personal injury or property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure loca...

Page 5: ...ailure to properly drain condensed water from tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the tank 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments 4 Excessive vibration can weaken the air tank and cause ruptu...

Page 6: ...pressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insectici...

Page 7: ...ause serious injury if they come into contact with you or your clothing Never operate the compressor with guards or covers which are damaged or removed Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be perform...

Page 8: ...horized parts HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF UNSAFE OPERATION Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF SERIOUS INJURY OR PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oi...

Page 9: ...omatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off...

Page 10: ...low Gun Adapter Blow Gun Safety Nozzle Blow Gun Tire Chuck Male Quick Connect Plugs Thread Seal Tape Tire Gauge Accessories Bag Female Quick Connect Plug AMOUNT 1 1 1 1 1 1 1 1 1 1 1 1 1 A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 A 12 A 13 Assemble Accessories The unit is supplied with an accessory kit and inflator deflator kit choose the accessory needed 10 ...

Page 11: ...e no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the tool If any parts are damaged or missing please call 1 877 888 3872 for assistance PACKING LIST Air Compressor Air Compressor Accessories 13 NOTE Accessory items are located in the front compartment of the compressor Open to check Operator s Manual...

Page 12: ...to compressor Fig A 1 Using your left hand push quick connect towards the body of the compressor 2 Firmly press fit the male quick connect portion on the air hose into the female quick connect and release female quick connect locking hose in place NOTE When connecting or disconnecting air hose remove air from tank 12 ...

Page 13: ...he blow gun c to hose b Risk of unsafe operation If an accessory is not being used with the blow gun the safety nozzle MUST be assembled 2 Assemble the safety nozzle d or blow gun adapter e to blow gun NOTE To use the inflating needle f or the tapered inflator g or rubber blow gun tip h need to use the blow gun adapter e to assembled to the blow gun 3 Attach the inflation needle f to the blow gun ...

Page 14: ...the blow gun to hose 2 Attach blow gun adapter to blow gun 3 Attach the inflation needle f tapered nozzle g Quick Connect Fig E 1 Assemble the 1 4 female quick connect plug k or 1 4 male quick connect plug to the 1 4 Female quick connect body 2 Attach the quick connect plug to the hose NOTE Always use PTFE tape on all threaded components to prevent leaks NOTE FEMALE QUICK CONNECT SOLD SEPARATELY j...

Page 15: ...ompressor should be located at least 12 away from the wall or other obstructions that will restrict the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventilation openings on the compressor are necessary to maintain proper operating temperature Do not place rags or other containers on or near these openings ...

Page 16: ...ON GROUNDING INSTRUCTIONS Fig F DANGER IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE AN ADAPTER See illustration 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounde...

Page 17: ...n the air tank pressure reaches the factory set cut out pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure ava...

Page 18: ...th the high flow inflator deflator adapter body Thread Seal Tape Used with inflator deflator nozzles to prevent air from leaking out of inflatables with very large air inlets Drain Valve not shown The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use Air Compressor Pump not shown Compresses air into the air tank Working air is not available...

Page 19: ...ator outlet pressure must never exceed the maximum pressure rating How to Start Fig H 1 Turn the Off Auto On switch to Auto On and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 2 Turn the regulator knob clockwise until desired pressure is reached NOTE To use the suggested pressure readings on the label turn the regulator knob clockwise until the needle on...

Page 20: ...obility 1 Slide handle out until it locks into place Fig I 3 To lower handle push handle until it snaps into place for storage 2 Pull or push unit as shown IMPORTANT This handle is for pushing or pulling the unit DO NOT lift the unit by this handle Fig J Fig I Fig J ...

Page 21: ...y also attach the tire chuck to a male quick connect for quick and easy removal in the future 2 Connect hose to compressor and turn switch to ON position Allow pressure to build up to maximum pressure level in tank 3 Adjust regulator pressure to MAXIMUM position In maximum output pressure position 135psi the tire will fill up quicker and accurately however it is extremely important to monitor the ...

Page 22: ...r pressure NOTE See Operation section for the location of controls To Check Safety Valve Risk of Bursting If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly contact a train...

Page 23: ...til air pressure is minimized 4 Place unit on blocks to lift unit off of ground 5 Place suitable container under unit to catch water 6 Slightly tilt unit and turn drain valve counter clockwise to open 7 Place unit back onto blocks to drain water from air tank 8 After the water has been drained close the drain valve clockwise The air compressor can now be stored Risk of Bursting Water will condense...

Page 24: ...sory storage located on back of unit Fig M 3 Wrap the electrical cord loosely snap it into itself as shown for storage 4 Store the air compressor in a clean and dry location Fig M Fig N Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture WARNING Before opening the storage door please make sure the power c...

Page 25: ...ng Check any exposed fittings with soapy water solution Do Not overtighten Apply sealant tape to threads of exposed fittings Air leak from safety valve Possible defect in safety valve Operate safety valve manually by pulling on ring If valve still leaks Contact a Trained Service Technician Tire will not fill with air Air pressure output on compressor is set to low Air pressure output from compress...

Page 26: ...uit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit 2 Check the extension cord 3 Check wiring connection inside...

Page 27: ...27 PART LISTS ...

Page 28: ...4117110 34116110 3220375 34102110 3220245 31104110 34115110 3220175 33206110 3290440 1 1 1 1 2 1 7 1 1 1 2 1 2 1 1 1 4 1 1 1 1 1 16 1 6 2 2 4 2 2 safety valve regulator subassembly pressure switch copper pin pressure gauge quick connect screw handle board right switch button handle screw handle board left screw switch board power switch pulling handle screw top housing cord managerment cord manage...

Page 29: ...02108 33905110 33303110 3220323 36301108 1 34901110 3790175 36401110 3420251 1 32202110 3320875 1 3320975 1 Ø10 clip ring motor pump assembly soft tube Ø14 clip ring single direction valve aluminium tube tank copper connector drain valve front housing rubber feet screw foot clip screw shaft bushing rotated shaft velcro piece storage cover steel plate screw magnet magnet board screw overload protec...

Page 30: ... of improper chemicals negligence accident failure to operate the product in accordance with the instructions provided in the Owners Manual s supplied with the product improper maintenance the use of accessories or attachments not recommended by the manufacturer or unauthorized repair or alterations An air compressor that pumps air more than 50 during a one hour period is considered misuse because...