8- ENG
D28752
GLOSSARY
DUTY CYCLE
Become familiar with these terms before operating the unit.
CFM
: Cubic feet per minute.
SCFM:
Standard cubic feet per minute; a unit of measure of air delivery.
PSIG:
Pounds per square inch gauge; a unit of measure of pressure.
Code Certification:
Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent
safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.
Cut-In Pressure:
While the motor is off, air tank pressure drops as you
continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically. The low pressure at which the motor
automatically restarts is called “cut-in” pressure.
Cut-Out Pressure:
When an air compressor is turned on and begins to run,
air pressure in the air tank begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity. The high pressure at which the motor shuts
off is called “cut-out” pressure.
Branch Circuit:
Circuit carrying electricity from electrical panel to outlet.
SPECIFICATIONS
Model No.
Y6010
Horsepower Peak
3.0
Bore
1.875"
Stroke
1.25"
Voltage-Single Phase
120V
*
Minimum Branch Circuit Requirement
15 amps
* *
Fuse Type
Time Delay
Air Tank Capacity - (gallon)
25
Approximate Cut-in Pressure
120 PSIG
Approximate Cut-out Pressure
150 PSIG
SCFM @ 40 PSIG
4.9
SCFM @ 90 PSIG
3.5
*
These compressors can be operated on a 15 amp circuit if:
1. Voltage supply to circuit must comply with the National Electrical Code.
2. Circuit is not used to supply any other electrical needs (lights, appliances, etc.)
3. Extension cords comply with specifications in owners manual.
4. Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.
If any of the above conditions cannot be met, or if operation of the compressor repeat-
edly causes interruption of the power it may be necessary to operate it from a 20 amp
circuit. It is not necessary to change the cord set.
** A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating
as the branch circuit on which the air compressor is operated. If compressor is
connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses
should be marked "D" in Canada and "T" in the US.
This air compressor pump is capable of running continuously. However, to
prolong the life of your air compressor, it is recommended that a 50%-75%
average duty cycle be maintained; that is, the air compressor pump should not
run more than 30-45 minutes in any given hour.
Summary of Contents for D28752
Page 58: ...58 FR D28752 NOTES...
Page 59: ...59 FR D28752 NOTES...