background image

12

13

OPERATION

WARNING:

Do not allow familiarity with tools to make you careless. 
Remember that a careless fraction of a second is
sufficient to inflict serious injury.

WARNING:

Always wear safety goggles or safety glasses with side 
shields when operating power tools. Failure to do so 
could result in objects being thrown into your eyes
resulting in possible serious injury.

CAUTION:

Do not use in an environment that is dusty or otherwise 
contaminated. Using the air compressor in this type of 
environment may cause damage to the unit.

APPLICATIONS

Air compressors are utilized in a variety of air system ap-
plications. Match hoses, connectors, air tools, and acces-
sories to the capabilities of the air compressor.
You may use this tool for the purposes listed below:

Operating some air-powered tools

Removing dust 

USING THE AIR COMPRESSOR

See Figures 5 - 9.

n

  Ensure power switch is in the 

OFF ( O ) 

position and air 

compressor is unplugged.

n

  If not already installed, attach hose to compressor as 

previously instructed. The hose should be inserted 
into the top quick connect coupler if your application 
requires an air pressure of 90 psi, or into the bottom 
quick connect coupler if a pressure of 40 psi is desired.

n

  Insert the blower attachment or connector for the tool 

you wish to use into the female connector on the other 
end of the spiral hose.

WARNING: 

Always ensure the switch is in the 

OFF ( O ) 

position 

and the regulator pressure gauge reads zero before 
changing air tools or disconnecting the hose from the 
air outlet. Failure to do so could result in possible seri-
ous personal injury.

n

  Connect the power cord to the power supply.

n

  Turn the switch 

ON ( l )

.

n

  Following all safety precautions in this manual and the 

manufacturer’s instructions in the air tool manual, you 

Fig. 7

HOSE WITH QUICK 

CONNECT COUPLER 

ATTACHED

BLOWER 

ATTACHMENT

may now proceed to use your air-powered tool or the 
blower attachment.

WARNING:

Your tool may require more air consumption than this 
air compressor is capable of providing. Check the tool 
manual to avoid damage to the tool or risk of personal 
injury.

n

  When using the blower attachment, the amount of air 

pressure can be further controlled by the amount the 
lever of the attachment is depressed.  

 

NOTE:

  Always use the minimum amount of pressure 

necessary for your application. Using a higher pressure 
than needed will drain air from the tank more rapidly 
and cause the unit to cycle on more frequently.

n

  When finished, always drain the tank and unplug the 

unit. Never leave the unit plugged in and/or running 
unattended.

Fig. 8

Fig. 9

AIR

CHUCK

1/4 in. NPT 

MALE CONNECTOR

HOSE WITH 

QUICK COUPLER 

ATTACHED

1/4 in. NPT 

MALE CONNECTOR

HOSE WITH QUICK 

COUPLER ATTACHED

INFLATION

ACCESSORIES

SAFETY NOZZLE

1/4 in. NPT 

MALE CONNECTOR

Summary of Contents for H1301F

Page 1: ...ty ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a Husky product OPERATOR S MANUAL 1 GALLON PORTABLE AIR COMPRESSOR H1301F ...

Page 2: ...sor pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 Compressed Gas Association 4221 Walney Road Fifth Floor Chantilly VA 20151 2923 703 788 2...

Page 3: ...al safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protec tion equipment When required the employer and user...

Page 4: ...must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress tank and allow water to drain and allow air compressor to become cool to the touch before servicing Turn pressure regulator knob fully clockwise after shutting off compressor n When servicing a tool u...

Page 5: ...n this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal injury n Never direct a jet of compressed air toward people or animals Take care not to blow dust and dirt towards yourself or others Following this rule wi...

Page 6: ...ns that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spraying area as possible at least 15 feet from the spraying area and all explosive vapors Wet Conditions Alert Class II Construction Hz Hertz A Amperes V Volts Hot Surface To reduce the...

Page 7: ...ANGER WARNING CAUTION CAUTION Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Without Safety Alert Symbol Indicates a situation that ma...

Page 8: ... cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension cord heavy enough to carry the current that the compressor will draw An undersized extension cord will cause a drop in line voltage resulting in a loss of power and causing the motor to overheat Use the...

Page 9: ...d within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed air Check Valve Device that prevents compressed air from flowing back from the air tank to the compressor pump Cut In Pressure The low pressure at which the motor will automatically restart Cut Off Pr...

Page 10: ... 1 5 in diameter Input 120 V 60 Hz AC only 11 5 Amps Net Weight 23 lbs Fig 2 COIL HOSE ON OFF SWITCH SAFETY VALVE TANK PRESSURE GAUGE 90 PSI AIR OUTLET 40 PSI AIR OUTLET POWER CORD DRAIN VALVE BUILT IN CORD WRAP AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER SEAL THREAD TAPE INFLATION ADAPTER INFLATION NEEDLE INFLATION NOZZLES BLOWER ATTACHMENT 1 4 in NPT FEMALE CONNECTOR FITTING SAFETY...

Page 11: ...ation and removal of the air hose BUILT IN CORD WRAP A built in cord wrap is provided for convenience in moving and storing the unit OIL FREE UNIVERSAL MOTOR Your air compressor features permanently lubricated bear ings SAFETY VALVE The safety valve is designed to automatically release air if the air receiver pressure exceeds the preset maximum TANK PRESSURE GAUGE The tank pressure gauge indicates...

Page 12: ...thers n Insert the female connector end of the coil hose into the desired air outlet on the air compressor Push the connector firmly until you hear it click into place n To disconnect the hose push the external ring nut of the quick coupler backward BREAKING IN THE PUMP See Figures 5 6 n Check and tighten all bolts fittings etc n Place the switch in the OFF position and plug in the power cord n Op...

Page 13: ...o use into the female connector on the other end of the spiral hose WARNING Always ensure the switch is in the OFF O position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible seri ous personal injury n Connect the power cord to the power supply n Turn the switch ON l n Following all safety ...

Page 14: ...from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand n Turn the air compressor on and allow the tank to fill The compressor will shut off when the pre...

Page 15: ...using compressed air LUBRICATION All of the bearings in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WARNING When servicing use only identical Husky replacement parts Use of any other parts may create a hazard or cause product damage WARNING Always w...

Page 16: ...electrical appli ances from circuit or operate com pressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload protector cuts out repeatedly Low voltage Lack of proper ventilation room temperature too high Wrong gauge wire or length of extension cord Check with voltmeter Move compressor to well ventilated area Check for proper ga...

Page 17: ...ecified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc product that has been altered or modified The warranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either INCOMPATIBLE WITH THE ONE WORLD TE...

Page 18: ...tinent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the air tank Please record the model number and serial number in the space provided below HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following information MODEL NUMBER SERIAL NUM...

Reviews: