background image

12

13

OPERATION

WARNING:

Do not allow familiarity with tools to make you careless. 
Remember that a careless fraction of a second is
sufficient to inflict serious injury.

WARNING:

Always wear safety goggles or safety glasses with side 
shields when operating power tools. Failure to do so 
could result in objects being thrown into your eyes
resulting in possible serious injury.

CAUTION:

Do not use in an environment that is dusty or otherwise 
contaminated. Using the air compressor in this type of 
environment may cause damage to the unit.

APPLICATIONS

Air compressors are utilized in a variety of air system ap-
plications. Match hoses, connectors, air tools, and acces-
sories to the capabilities of the air compressor.
You may use this tool for the purposes listed below:

Operating some air-powered tools

Inflating tires, air beds, sports equipment, etc.

USING THE AIR COMPRESSOR

See Figures 8 - 9.

n

  Ensure power switch is in the 

OFF (O) 

position and air 

compressor is unplugged.

n

  If not already installed, attach hose to compressor as 

previously instructed.

n

  Attach 1/4 in. NPT male connector fitting to accessory 

or tool you intend to use.

n

  Insert the other end of the male connector to the quick 

coupler on the open end of hose.

WARNING: 

Always ensure the switch is in the 

OFF (O) 

position and 

the regulator pressure gauge reads zero before chang-
ing air tools or disconnecting the hose from the air 
outlet. Failure to do so could result in possible serious 
personal injury.

n

  Rotate regulator knob fully clockwise to open air flow. 

Turn the locking nut clockwise to lock.

n

  Connect the power cord to the power supply.

n

  Turn the switch 

ON ( l )

.

n

  Rotate pressure regulator knob to desired line pres-

sure. Turning the knob clockwise increases air pres-
sure at the outlet; turning counterclockwise reduces air 
pressure at the outlet.

n

  Following all safety precautions in this manual and the 

manufacturer’s instructions in the air tool manual, you 
may now proceed to use your air-powered tool.

WARNING:

Your tool may require more air consumption than this 
air compressor is capable of providing. Check the tool 
manual to avoid damage to the tool or risk of personal 
injury.

n

  If using an inflation accessory, control the amount of air 

flow with the pressure regulator knob. Turning the knob 
fully counterclockwise will completely stop the flow of 
air.

 

NOTE:

  Always use the minimum amount of pressure 

necessary for your application. Using a higher pressure 
than needed will drain air from the tank more rapidly 
and cause the unit to cycle on more frequently.

n

  When finished, always drain the tank and unplug the 

unit. Never leave the unit plugged in and/or running 
unattended.

Fig. 8

Fig. 9

AIR

CHUCK

1/4 in. NPT 

MALE CONNECTOR

HOSE WITH 

QUICK COUPLER 

ATTACHED

HOSE WITH QUICK 

COUPLER ATTACHED

INFLATION ADAPTER INSTALLED 

ON MALE CONNECTOR FITTING

INFLATION

ACCESSORIES

Summary of Contents for H1506F

Page 1: ...y ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the op...

Page 2: ...or pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D...

Page 3: ...l safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any...

Page 4: ...ust be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress t...

Page 5: ...this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rul...

Page 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Page 7: ...beginning power tool operation always wear safety goggles safety glasses with side shields or a full face shield when needed We recommend Wide Vision Safety Mask for use over eyeglasses or standard sa...

Page 8: ...cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension co...

Page 9: ...within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed a...

Page 10: ...Input 120 V 60 Hz AC only 12 Amps Net Weight 40 8 lbs COIL HOSE INFLATION NOZZLE INFLATION NOZZLE INFLATION ADAPTER INFLATION NEEDLE AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER MANUAL O...

Page 11: ...been shipped completely assembled n Carefully remove the tool and any accessories from the box Make sure that all items listed in the packing list are included n Inspect the tool carefully to make sur...

Page 12: ...Check and tighten all bolts fittings etc n Turn the pressure regulator knob fully clockwise to open the air flow Turn the locking nut clockwise to lock n Place the switch in the OFF position and plug...

Page 13: ...o before chang ing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury n Rotate regulator knob fully clockwise to open air flow Tu...

Page 14: ...s personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand...

Page 15: ...in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WA...

Page 16: ...isconnect other electri cal appliances from circuit or operate compressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload prote...

Page 17: ...cified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc pr...

Page 18: ...inent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the a...

Reviews: