SPEED AND WIRING

The no-load speed of this air compressor is approximately 
26,000 rpm. This speed is not constant and decreases 
under a load or with lower voltage. For voltage, the wiring 
in a shop is as important as the motor’s horsepower rat-
ing. A line intended only for lights cannot properly carry 
a power tool motor. Wire that is heavy enough for a short 
distance will be too light for a greater distance. A line that 
can support one power tool may not be able to support 
two or three tools.

GROUNDING INSTRUCTIONS

In the event of a malfunction or breakdown, grounding 
provides a path of least resistance for electric current 
to reduce the risk of electric shock. This air compressor 
is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug 
must be plugged into a matching outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a qualified electrician. 
Improper connection of the equipment-grounding con-
ductor can result in a risk of electric shock. The conduc-
tor with insulation having an outer surface that is green 
with or without yellow stripes is the equipment-grounding 
conductor. If repair or replacement of the electric cord or 
plug is necessary, do not connect the equipment-ground-
ing conductor to a live terminal.
Check with a qualified electrician or service personnel if 
the grounding instructions are not completely understood, 
or if in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
This air compressor is intended for use on a circuit that 
has an outlet like the one shown in figure 1. It also has a 
grounding pin like the one shown. This product must be 
grounded.

ELECTRICAL

Fig. 1 

EXTENSION CORDS

Use only 3-wire extension cords that have 3-prong 
grounding plugs and 3-pole receptacles that accept the 
air compressor’s plug. When using the air compressor at 
a considerable distance from the power source, use an 
extension cord heavy enough to carry the current that the 
compressor will draw. An undersized extension cord will 
cause a drop in line voltage, resulting in a loss of power 
and causing the motor to overheat. Use the chart pro-
vided below to determine the minimum wire size required 
in an extension cord. Only round jacketed cords listed by 
Underwriter’s Laboratories (UL) should be used.

**Ampere rating  (on air compressor data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

  25' 

16 

16 

16 

16 

14 

14

  50' 

16 

16 

16 

14 

14 

12

  100' 

16 

16 

14 

12 

10 

**Used on 12 gauge - 20 amp circuit.

NOTE:

 AWG = American Wire Gauge

When working with the air compressor outdoors, use an 
extension cord that is designed for outside use. This is 
indicated by the letters “WA” on the cord’s jacket.
Before using an extension cord, inspect it for loose or 
exposed wires and cut or worn insulation.

WARNING:

Keep  the  extension  cord  clear  of  the  working  area.
Position the cord so that it will not get caught on lumber, 
tools, or other obstructions while you are working with 
a power tool. Failure to do so can result in serious per-
sonal injury.

WARNING:

Check  extension  cords  before  each  use.  If  damaged,
replace  immediately.  Never  use  air  compressor  with  a 
damaged cord since touching the damaged area could 
cause electrical shock resulting in serious injury.

NOTE: 

Use longer air hoses instead of long extension 

cords. Your air compressor will run better and last longer.

ELECTRICAL CONNECTION

This air compressor is powered by a precision built 
electric motor. It should be connected to a 

power sup-

ply that is 120 volts, 60 Hz, AC only (normal household 
current). 

Do not operate this tool on direct current (DC). 

A substantial voltage drop will cause a loss of power and 
the motor will overheat. If the air compressor does not 
operate when plugged into an outlet, double check the 
power supply.

GROUNDING

PIN

120V GROUNDED OUTLET

Summary of Contents for H1506F

Page 1: ...y ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the op...

Page 2: ...or pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D...

Page 3: ...l safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any...

Page 4: ...ust be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress t...

Page 5: ...this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rul...

Page 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Page 7: ...beginning power tool operation always wear safety goggles safety glasses with side shields or a full face shield when needed We recommend Wide Vision Safety Mask for use over eyeglasses or standard sa...

Page 8: ...cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension co...

Page 9: ...within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed a...

Page 10: ...Input 120 V 60 Hz AC only 12 Amps Net Weight 40 8 lbs COIL HOSE INFLATION NOZZLE INFLATION NOZZLE INFLATION ADAPTER INFLATION NEEDLE AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER MANUAL O...

Page 11: ...been shipped completely assembled n Carefully remove the tool and any accessories from the box Make sure that all items listed in the packing list are included n Inspect the tool carefully to make sur...

Page 12: ...Check and tighten all bolts fittings etc n Turn the pressure regulator knob fully clockwise to open the air flow Turn the locking nut clockwise to lock n Place the switch in the OFF position and plug...

Page 13: ...o before chang ing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury n Rotate regulator knob fully clockwise to open air flow Tu...

Page 14: ...s personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand...

Page 15: ...in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WA...

Page 16: ...isconnect other electri cal appliances from circuit or operate compressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload prote...

Page 17: ...cified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc pr...

Page 18: ...inent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the a...

Reviews: