12
ASSEMBLY
ATTACHING HOSE
Attach the supplied quick-connect fitting to hose (note:
wrap threaded ends with supplied thread sealing tape
before securing fittings to hose).
Push male end of hose into quick coupler already
installed on the compressor.
BREAKING IN THE PUMP
See figure 3 - 5
Check and tighten all bolts, fittings, etc.
Turn the pressure regulator knob fully clockwise to
open the air flow.
Place the switch in the
OFF (0)
position and plug in the
power cord.
Open the drain valve completely.
Place the switch in the
ON ( l )
and run the air
compressor for 10 minutes to break in pump parts.
Place the switch in the
OFF (0)
position.
Close the drain valve.
WARNING:
Do not attach any tools to the open end of the hose until
start-up has been completed.
QUICK COUPLER
Fig. 3
Fig. 4
Fig. 5
SWITCH
PRESSURE REGULATOR KNOB
DRAIN VALVE