background image

 

Filter indicator 

A 600 / A 1200 has two filter indicators connected to a warning light which measures the pressure 
drop over the filter. If the pressure drop is too high, a yellow lamp light up, indicating that the pre-
filter should be changed. When the Yellow light stays on even after a pre-filter change. It is time to 
Change the HEPA filter. Using the air scrubber when light is showing will reduce the effectiveness of 
the machine. When the pressuredrop is too low, a red lamp will light up, indicating that the Hepa filter 
is leaking/damaged and needs to be replaced immediately. 
Please note that the filter indicators only does work at full speed. 
Recommended intervals for filter change: Socks filter every 6 months and Hepa filter every 12 month.  
 
 

Fan 

The air scrubber is equipped with a single, 1 phase fan. 

 

Risk of dust dispersion - Use of personal safety equipment 
Unhealthy dust can be spread when cleaning the coarse filter and during filter change. 
Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask 
conforming to protection class FFP2.

 

 
 

Accessories 

PART NO. 

DESCRIPTION 

No./machine 

Machine 

590430001 

Pre-filter 20-pcs 

1 ea 

A 600 

590460801 

HEPA filter 

1 ea 

A 600 

590430002 

Pre-filter 20-pcs 

1 ea 

A 1200 

590463201 

HEPA filter 

1 ea 

A 1200 

Contact your local representative for other spare parts. 
 
 

Warranty 

All Husqvarna devices and accessories have a 12-month factory warranty from the date of purchase 
for material and manufacturing defects. Do not attempt to repair the suction apparatus without the 
consent of the manufacturer.  
 
The warranty does not cover defects which are the result of normal wear and tear, negligence, 
defective use, unauthorised repair or the suction apparatus being connected to the incorrect voltage. 
In the event of any complaint, the suction apparatus or an agreed part of it must be returned to us or 
our authorised representative for warranty examination and for any warranty repair or replacement.

 

 
 

Summary of Contents for A 600

Page 1: ...Operator s manual A Line Air Scrubber Please read the operator s manual carefully and make sure you understand the instructions before using the machine US A 600 A 1200 ...

Page 2: ...ations or has been used in ways other than those outlined in this instruction manual Before using the machine please read the safety regulations carefully Read the complete instruction manual before using the Husqvarna A 600 A 1200 All spare parts used for the Husqvarna A 600 A 1200 must those specified by Husqvarna Construction Products Type plate CHINA CHINA Unpacking When unpacking the machine ...

Page 3: ...ty equipment to use and how to work in a safe mode Warning Cables damaged through crushing or splitting can be dangerous if used and should be replaced immediately Risk of personal injury Warning Do not connect the machine to an unearthed socket Risk of personal injury Warning Make sure the assembly area is firm so the air scrubber does not tip over Risk of personal and material injury Stop button...

Page 4: ...t the lead to the power outlet attach the outlet hose if available Start the machine by pressing the start knob The air scrubber has two speeds The air scrubber separates material in two stages The first stage uses a coarse filter This traps the bigger particles and acts as protection for the main filter The coarse filter should be changed on a daily basis The second absolute filter separates the ...

Page 5: ... can be spread when cleaning the coarse filter and during filter change Accordingly the user should wear protective glasses protective gloves and a breathing mask conforming to protection class FFP2 Accessories PART NO DESCRIPTION No machine Machine 590430001 Pre filter 20 pcs 1 ea A 600 590460801 HEPA filter 1 ea A 600 590430002 Pre filter 20 pcs 1 ea A 1200 590463201 HEPA filter 1 ea A 1200 Cont...

Page 6: ...ly Wrong fuse Connect the correct fuse The fan runs Blocked filter Change filter but suction is poor Cover loose Adjust Sealing defect Change current seal Dust blows from unit Defective or loose filter Adjust or change Abnormal noise Order service Keep these instructions TECHNICAL DATA Air scrubber A 600 A 1200 Power 0 385 kW 0 5 HP 0 585 kW 0 8 HP Voltage 120 120 V Current 3 2 A 4 9 A Power suppl...

Page 7: ..._ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ...