BE 20
BE 30
Power, kW/hp @rpm
0.45/0.6 @3600
2.6/3.5 @3600
1
Full load current, A
0.8
N/A
Engine brand, type *
N/A
Honda, GX120
Fuel *
N/A
Unleaded gasoline, max. 10%
ethanol
Fuel tank capacity, l/qts
N/A
2/1.8
Oil tank capacity, l/qts
N/A
0.6/0.52
Drive unit dimensions, L×W×H mm/ft
N/A
305×341×329/1.00×1.10×1.07
Total weight, kg/lb
37/81.6
32/70.5
* = For further information and questions about this
specific engine, refer to the engine manual or the web
site of the engine manufacturer.
Beams
Height, mm/in.
Total width,
mm/in.
Total length, m/ft
Weight, kg/lb
Deflection, mm/in.
BD 32
100/3.93
400/15.74
3.2/10.5
32/70.5
8–9/0.31–0.35
BD 42
100/3.93
400/15.74
4.2/13.8
41/90.4
11–12/0.43–0.47
BD 52
100/3.93
400/15.74
5.2/17.1
47/103.6
13–14/0.51–0.55
BD 62
100/3.93
400/15.74
6.2/20.3
57/125.7
18–20/0.71–0.78
Noise and vibration emissions
BE 20
BE 30
Sound power level, guaranteed L
WA
dB (A)
2
94
103.8
Sound pressure level at the operator's ear, L
P
, dB (A)
3
N/A
75.7
Vibration level, a
hv
, m/s
2
4
2.5
3.0
Noise and vibration declaration
statement
These declared values were obtained by laboratory type
testing in accordance with the stated directive or
standards and are suitable for comparison with the
declared values of other products tested in accordance
with the same directive or standards. These declared
values are not suitable for use in risk assessments and
values measured in individual work places may be
higher. The actual exposure values and risk of harm
experienced by an individual user are unique and
depend upon the way the user works, in what material
1
As specified by the engine manufacturer. The power rating of the engine indicated is the average net output
(at specified rpm) of a typical production engine for the engine model measured to SAE standard J1349/
ISO1585. Mass production engines may differ from this value. Actual power output for the engine installed on
the final product will depend on the operating speed, environmental conditions and other values.
2
Noise emissions in the environment measured as sound power (L
WA
) as per EN ISO 3744 in conformity with
EC directive 2000/14/EC. The difference between guaranteed and measured sound power is that the guaran-
teed sound power also includes dispersion in the measurement result and the variations between different
machines of the same model according to Directive 2000/14/EC.
3
Sound pressure level L
P
according to EN ISO 11201, EN 500-4. Uncertainty K
PA
3.5 dB (A).
4
Vibration value according to EN 500-4. Reported data for vibration level has a typical statistical dispersion
(standard deviation) of 1.5 m/s
2
.
1299 - 001 - 14.04.2020