10 –
English
STARTING AND STOPPING
Before starting
•
Check that the machine is assembled correctly and do not
show any signs of damage. See instructions in the section
"Assembling and adjustments".
•
Perform daily maintenance. See instructions in the section
"Maintenance".
Changing the dust bags
Once the dust bag has collected around 20 kg of dust, to
avoid lifting hazards caused by overfilling of dust bags, the
dust bag should be changed.
•
Clear the primary filters. See instructions under the
heading ”Cleaning the primary filters”.
•
Switch the machine back into ON position holding the dust
flap closed. (You will notice the air is sucked from the
plastic bag.)
•
Tie bag off below the collection cone using a cable tie or
other bag tie.
•
Release elastic strap and remove sealed bag.
•
Using elastic strap, attach new empty plastic bag (you will
notice the air is sucked from the plastic bag).
•
Machine is now ready to be used for dust collection again.
Starting
•
Position the vacuum in the working area.
•
Ensure dust collection bag is fitted to collection cone.
•
Check that the suction hose is secured to the connector.
•
Turn the switch to the ON position (I).
Stopping
Turn the switch to the OFF position (O).
!
WARNING! Please read the operator’s
manual carefully and make sure you
understand the instructions before using the
machine.
Wear personal protective equipment. See
instructions under the ”Personal protective
equipment” heading.
Make sure no unauthorised persons are in
the working area, otherwise there is a risk of
serious personal injury.
IMPORTANT! Use extreme caution when releasing and
reattaching elastic strap.
IMPORTANT! It is important to keep vacuum running during
the bag changing process. This will keep the valve in the
collection cone closed ensuring no dust will drop out from
within the collection cone when bag changing is being
performed.
!
WARNING! Ensure vacuum is set to OFF
position prior to turning on power supply.
0 I
0 I
Summary of Contents for DC5500