Note 1: Noise emissions in the environment measured as sound power (L
WA
) in conformity with EN 60335-2-69.
Note 2: Noise pressure level according to EN 60335-2-69. Reported data for noise pressure level has a typical statistical dispersion
(standard deviation) of 1.0 dB(A).
EC-declaration of conformity
(Applies to Europe only)
Husqvarna AB
, SE-433 81 Göteborg, Sweden, tel: +46-31-949000, declares under sole responsibility that the dust extraction unit
Husqvarna DC 5500
dating from 2010 serial numbers and onwards (the year is clearly stated on the rating plate, followed by the
serial number), complies with the requirements of the COUNCILíS DIRECTIVE:
•
of May 17, 2006 ”relating to machinery”
2006/42/EC
•
of December 15, 2004 ”relating to electromagnetic compatibility”
2004/108/EC
.
•
of December 12, 2006 ”relating to electrical equipment”
2006/95/EC
.
•
of June 8, 2011 ”relating to restriction of certain hazardouz substances”
2011/65/EU
The following standards have been applied: EN ISO 12100:2010, EN 55014-1:2006, EN 55014-2/A1:2001, EN 61000-3-2:2006,
EN 61000-3-3:2008, EN 60335-2-69:2009.
Gothenburg 19 September 2012
Anders Ströby
Vice President, Head of Power Cutters and Construction Equipment
Husqvarna AB
(Authorized representative for Husqvarna AB and responsible for technical documentation.)
DC 5500, 400V
Power, kW/hp
5,5/7,5
Rated voltage, V
380-440
Rated current, A
12
Power supply
3 phase
Air flow m
3
/h / cfm
550/325
Max. vacuum, bar/psi
0,3/4,35
Suction inlet diameter mm/inch
75/3
Primary filtration surface area, m
2
/ sq. ft. 2,2/24
Micro filter surface area, m
2
/ sq. ft.
6,6/71
Weight, kg/lbs
215/473
Size, (LxWxH), mm/inch
1100x660x1960 /
43x26x77
Noise emissions (see note 1)
Sound power level, measured dB (A)
92
Sound power level, guaranteed L
WA
dB
(A)
93
Sound levels (see note 2)
Sound pressure level at the operators ear,
dB(A)
77
Summary of Contents for DC5500