Nominal volt-
age from pow-
er source, V
Cable area,
AWG/mm
2
Start current,
A
Motor output,
kW
Setting ther-
mal overload
relay, A
Max. cable
length, m/ft
460
7/10
99
60 Hz
27
39
311/1020
460
5/16
99
27
39
498/1634
Sound levels
DXR 145
DXR 275
DXR 305
DXR 315
Noise emissions
7
Sound power level
without tool, meas-
ured dB(A)
92
87
87
87
Sound power level
without tool, guaran-
teed L
W
93
95
95
95
Sound power level
with tool (breaker,
measured dB(A)
113
118
118
118
Sound power level
with tool (breaker,
guaranteed L
W
114
118
118
118
Sound levels
8
Sound pressure lev-
el, 10 m from the
product tool
9
, dB (A)
87
90
90
90
7
Noise emission in the environment measured as sound power according to EC directive 2000/14/EC. The dif-
ference between the guaranteed and the measured noise level is a measurement of dispersion and variations
in the declared value.
8
Sound pressure level according to EG directive 2000/14/EG. Expected measurement uncertainty 2 dB(A).
9
The stated value refers to operation with a breaker. Other types of recommended tools create a considerably
lower noise level.
114
1401 - 002 - 15.10.2021