To do after maintenance
1. Do a test operation after maintenance is done.
WARNING:
Risk of injury and
damage. Incorrectly installed remote
control, cables or hoses can have an
unwanted effect on the movements of
the product.
2. If there is a fault, immediately stop the product. Refer
To stop the product (DXR 145) on page 62
stop the product (DXR 275, DXR 305, DXR 315) on
page 62
.
Troubleshooting
Troubleshooting
Problem
Cause
Solution
The product does not
start.
The main switch is off.
Do a check of the main switch.
The extension cable is disconnected or dam-
aged.
Connect the extension cable. Replace the
extension cable if it is damaged.
The emergency stop button on the product is
engaged.
Turn the emergency stop button on the prod-
uct clockwise to disengage.
The machine stop button on the remote con-
trol is engaged.
Turn the machine stop button on the remote
control clockwise to disengage.
Too low mains voltage to the product.
Do a check of the power supply. Make sure
that correct voltage is used.
A mains fuse is blown.
Make sure that the mains voltage is compati-
ble with the product and that the correct
fuses are used.
Do a check of the power cord.
No radio communication between the prod-
uct and the remote control.
Do a check of the radio signal. If there is no
radio signal, examine if the batteries for the
remote control are charged and correctly in-
stalled.
Make sure that correct remote control is
used.
Make sure that the communication cable and
the antenna cable on the product are correct-
ly attached.
Do a test operation of the product with a ca-
ble between the product and the remote con-
trol.
The fuses for the
mains connection
blow immediately af-
ter starting the prod-
uct.
The fuse for the mains connection have too
low rating value.
Make sure that the mains voltage is compati-
ble with the product and that the correct
fuses are used.
The electric motor is defective.
Speak to an approved service agent.
The power cord is defective.
Replace the power cord.
The hydraulic pump is defective.
Speak to an approved service agent.
1401 - 002 - 15.10.2021
91