Type,
3600
rpm
Centrifugal force, Lbs
ER
605
1012 1350 1687 2025 2362 2700
ER
705
1435 1913 2391 2869 3347 3825
Posi-
tion
1
2
3
4
5
6
To adjust the centrifugal force ER
207B, ER 407B and ER 507B
1. Remove the bolts and washers that hold the end
page 12
.
2. Remove the end covers.
3. Remove the bolts and the washers from each end of
the rotor.
4. Remove the eccentric weights from the shaft and
turn them 180° to adjust the centrifugal force. Refer
to
Eccentric weight adjustments for ER 207B, ER
407B and ER 507B, 200 Hz on page 10
and
Eccentric weight adjustments for ER 207B, ER 407B
and ER 507B, 180 Hz on page 10
.
CAUTION: Do the adjustments on each
end of the rotor.
Note: The positions of the eccentric weights are also
found on the inner side of the eccentric weights
covers. The factory positions for the products are set
to position 4.
5. Assemble the product. Refer to
.
Eccentric weight adjustments for ER
207B, ER 407B and ER 507B, 200 Hz
1
2
3
4
5
6
Type,
6000
rpm
Centrifugal force, N
ER
207B
700 2040 3380 4720
6050
7400
ER
407B
1000 3000 5000 7000
9000 11000
Type,
6000
rpm
Centrifugal force, N
ER
507B
1460 4380 7300 10220 13080 16000
Position
1
2
3
4
5
6
Eccentric weight adjustments for ER
207B, ER 407B and ER 507B, 180 Hz
1
2
3
4
5
6
Type,
5400 rpm
Centrifugal force, Lbs
ER 207B
120
365
610
855
1100 1345
ER 407B
180
540
540
1260 1620 1980
ER 507B
270
810 1350 1890 2430 2970
Position
1
2
3
4
5
6
To reverse the vibration
• Change the positions of the phase wires in the
power supply cable. Refer to
page 21
.
Note: A table with the correct connections is found in
the terminal box.
To do a function check before
operation
1. Assemble the product. Refer to
product on page 13
.
2. Make sure that the product is correctly assembled.
Make sure that the rotor shaft turns freely and is not
loose.
3. Do a check of the motor insulation to ground. Use a
multimeter at 2.2 kV for 5 seconds.
4. Make sure that the product is connected to the
correct voltage. Refer to
Technical data on page
17
.
5. Do a check with a multimeter that the current is not
more than the value specified on the rating plate.
10