English – 27
TECHNICAL DATA
Technical data
Note 1: Noise emissions in the environment measured as sound power (L
WA
) conforming to EN 60745-1.
Note 2: Noise pressure level according to EN 60745-1. Reported data for noise pressure level has a typical statistical
dispersion (standard deviation) of 1.0 dB(A).
Note 3: Equivalent vibration level, according to EN 60745-2-22, is calculated as the time-weighted energy total for
vibration levels under various working conditions. Reported data for vibration level has a typical statistical dispersion
(standard deviation) of 1,5 m/s
2
.
Cutting equipment
Technical data
K6500 Ring
Motor
Electric motor
HF High Frequency
Max. speed of output shaft, rpm
9000
3-phase operation, Motor output - max. kW
5,5
1-phase operation, Motor output - max. kW
3
Weight
Machine with cable packadge, without blade, kg
13.1
Water cooling
Water cooling of blade
Yes
Max. recommended water pressure, bar
8
Min. recommended water flow, l/min
4 at water temperature 15
°
C
Connecting nipple
Type ”Gardena”
Noise emissions (see note 1)
Sound power level, measured dB (A)
110
Sound power level, guaranteed dB(A)
111
Sound levels (see note 2)
Sound pressure level at the operators ear, dB(A)
99
Equivalent vibration levels, a
hveq
(see note 3)
Front handle, m/s
2
2.4
Rear handle, m/s
2
1,5
Cutting blade, mm
350
Max. peripheral speed, m/s
55
Max. blade speed, rpm
3000
Max cutting depth, mm
270