TROUBLE SHOOTING
Fault LD8
LD19
LD8 and LD19
Green
Red
Green and Red
Electrical connection, start of cutting unit (P.T.O).
Voltage out.
Short circuit, probably on the cabling or in the electrical connec-
tion.
Open circuit, it electrical connection or on the negative conduc-
tor out to the electrical connection.
LD9
LD21
LD9 and LD21
Green
Red
Green and Red
Blinkers right.
Voltage out.
Short circuit, probably on the cabling or in the bulbs.
Open circuit, probably the conductor out to the bulbs or in the
negative conductor to the bulbs.
LD10
LD22
LD10 and LD22
Green
Red
Green and Red
Blinkers left.
Voltage out.
Short circuit, probably on the cabling or in the bulbs.
Open circuit, probably the conductor out to the bulbs or in the
negative conductor to the bulbs.
LD11
LD20
LD11 and LD20
Green
Red
Green and Red
Injection pump, voltage = start and operation.
Voltage out.
Short circuit, probably on the cabling out to injection pump.
Open circuit, probably on the cabling out to the injection pump
or on its conductor or on the injection pump.
LD23
Green
Starter motor, voltage = starter motor activated.
Voltage out, if the LED does not light on activation of the starter
motor there may be a short-circuit as this circuit has no red LED
to indicate a short circuit. The circuit is short-circuit protected, in
the event of a short-circuit the green LED does not comes on.
Loosen the connection on the starter motor's magnetic coupler
and activate the starter motor, if the LED now lights the mag-
netic coupler is short circuited. coupler
LD24
Green
Glow plug heating, voltage = glow plug heating in
progress.
Voltage out, if the LED does not light on activation of the glow
plug heating there may be a short-circuit as this circuit has no
red LED to indicate a short circuit. The circuit is short-circuit pro-
tected, in the event of a short-circuit the green LED does not
comes on. Loosen the connection to glow plug heating and acti-
vate glow plug heating, if the LED comes on it is short circuited.
Check the glow plug, etc.
LD25
Green
High beam, voltage = high beam activated.
Voltage out, if the LED does not light on activation of the high
beam there may be a short-circuit as this circuit has no red LED
to indicate a short circuit. The circuit is short-circuit protected, in
the event of a short-circuit the green LED does not comes on.
Check the bulb and cable harness.
LD26
Green
Low beam, voltage = low beam activated.
Voltage out, if the LED does not light on activation of the low
beam there may be a short-circuit as this circuit has no red LED
to indicate a short circuit. The circuit is short-circuit protected, in
the event of a short-circuit the green LED does not comes on.
Check the bulb and cable harness
Summary of Contents for PT 26D
Page 1: ...Workshop manual PT26D English ...
Page 13: ...English 12 SPECIAL TOOLS ...
Page 94: ...English 93 REPAIR INSTRUCTIONS 8043 197 Cutting unit Combi 155 ...
Page 107: ...English 106 REPAIR INSTRUCTIONS ...
Page 123: ...English 122 REPAIR INSTRUCTIONS ...
Page 145: ......
Page 146: ...English 145 APPENDIXES Circuit diagram Circuit diagram 1 ...
Page 147: ...English 146 APPENDIXES Circuit diagram 2 ...
Page 148: ...English 147 APPENDIXES Circuit diagram 3 ...
Page 149: ...English 148 APPENDIXES Circuit diagram 4 ...
Page 150: ...English 149 APPENDIXES Circuit diagram 5 ...
Page 151: ...English 150 APPENDIXES Circuit diagram 6 ...
Page 152: ...English 151 APPENDIXES Circuit diagram 7 ...
Page 153: ...English 152 APPENDIXES Circuit diagram 8 ...
Page 154: ...English 153 APPENDIXES Circuit diagram 9 ...
Page 155: ...English 154 APPENDIXES Circuit diagram 10 ...
Page 156: ...English 155 APPENDIXES Circuit diagram 11 ...
Page 157: ...English 156 APPENDIXES ...
Page 161: ...English 160 APPENDIXES 8043 160 Circuit board placement ...
Page 162: ...English 161 APPENDIXES Hydraulic diagram 8043 247 Hydraulic diagram ...
Page 163: ...English 162 APPENDIXES ...
Page 167: ...2009W18 115 08 30 26 ...