• All parts that are contaminated after service work
must be disposed in a correct procedure in plastic
bags. Refer to local regulations.
• Use correct personal equipment when you clean the
product. Refer to
Personal protective equipment on
page 6
.
• Clean the external surface with a moist cloth.
• Clean the filters and the dust extractor in applicable
area.
• Vacuum the pre-filter from the outside. Always use
dust extractors with HEPA-filter and a soft brush to
not damage the filter.
• Do not use water on electrical components.
• Do not clean the dust extractor with high pressure
(air or water).
• Do not put tools on the surface of the filter, it can
cause damage to the filter.
• Do not make a hole in the HEPA filter, it can cause a
health risk.
Filter change
WARNING: Use personal safety equipment,
refer to
Personal protective equipment on
page 6
, during filter change. Dust can come
out during filter change.
WARNING: Always turn the motor switch in
the Off position and disconnect the cord
from the wall outlet during filter change.
To change the HEPA filter
CAUTION: Do not clean HEPA filters. Trying
to clean a HEPA filter will destroy it. When
installing the replacement filter, make sure to
not touch the inside of the filter. Any kind of
force/damage on the inside of filter media
will destroy the new filter.
Note: Recommended intervals for filter change: Pre-
filter every 6 months and HEPA filters every 12 months.
1. Loosen the screws on the filter cover cap.
2. Carefully lift the filter into a clean plastic bag, this
bag must be properly disposed.
3. Insert a new filter in reverse order.
To change the pre-filter
CAUTION: When you remove the pre-filter
in order to clean it, use only low pressure
water from the inside through to the out.
Hitting the filter with force, high pressure
water or use of compressed air will destroy
the filter. The filter must be 100% dry before
returning into the housing.
1. Loosen the 3 toggle fastners and remove the top.
2. Take the bag from the new filter.
3. Lift out the filter and place it gently in a plastic bag.
This bag must be properly disposed.
4. Insert a new filter.
Troubleshooting
Troubleshooting schedule
Issue
Cause
Solution
Motor does not start
No power
Plug in machine
Cable defective
Replace cable
Switch defective
Replace switch
Soft start defective
Replace soft start
Motor stops immediately after
starting
Wrong fuse
Connect to correct fuse
Shortcut in cable/machine
Order service