Troubleshooting
Solution
Cause
Problem
Check the cables or converter. Replace the
cable or converter.
The RCD breaker has detected a fault.
The SMART stops during operation.
Check for short circuit between the phases
on the poker side.
The SMART microprocessor has detected a
fault.
The internal vibrator is overloaded (when
operating in concrete or rebar).
The SMART stops during operation.
Check for short circuit between the phases
and (ground) earth on the poker side.
Overload.
Overheating. This can occur when the
temperature of the cover casing is too high
>60°C (140°F)
Action
SMART status
LED status
-
No fault.
Connected to the power source.
Steady green.
Check if the vibrating head is blocked or
overloaded.
Work in progress.
Limitation of current.
Flashing green.
Let the converter or vibrating head cool down
for a few minutes then try to restart the poker.
Converter box is overheating.
Vibrating head is overheating.
Flashing red.
Check the voltage of the power source.
Overvoltage or undervoltage.
Flashing green and red.
Check the converter and vibrator head for
damage. If necessary send the poker to an
authorised workshop.
Overload.
Short circuit between phases.
Insulation fault in the vibrating head.
Internal problem in the converter.
Steady red.
© 2016 Construction Tools PC AB | No. 9800 1207 01d | 2016-06-21
Original instructions
18
SMART
Safety and operating instructions