OPERATING
12 - English
R297123
Stopping
• Press the button again to shut the pump down.
The pump shuts down automatically if the container runs
out of water.
Trouble shooting
Problem
Procedure
Steps
The diode on the
machine flashes
red three times
and it does not
start.
Battery flat
Charging the
battery
The machine does
not start even
if the battery is
charged.
The battery is in
the wrong battery
holder.
Check that the
battery is in the
right-hand battery
holder and not
in the "parking
space".
Air bubble in the
pump house.
Wait one minute
and start again.
The machine does
not pump water
when it starts,
but the pump is
running.
Blocked filter
mesh in the pump
holder.
Remove and clean
the pump.
Blockage in the
pump, possible
blocked filter
mesh.
Remove and clean
the pump.
The machine does
not pump water
when it starts, and
the pump is not
running.
Water frozen in
the pump.
Thaw the machine
slowly.
Low water flow
from the machine.
Blocked filter
mesh in the pump
holder.
Remove and clean
the pump.
The product is intended to be used with a number of
different power cutters and core drills on the market.
This product is not recommended for high performance
machines requiring high water flows/water pressures e.g.
diamond chain saws.