13
Installers: After running electrical you
MUST seal top (shown here) and bottom
of this pipe to eliminate any air
penetration!
Failure to do so will cause condensation
inside of pipe and water will drip on
floor!
Silicone is an acceptable material to
seal pipe.
Sealed refrigeration lines inside of
pipe.
This is an EXAMPLE of how to
properly seal electrical lines (using
silicone) once electrical lines are
pulled using provided wire-chase.
Sealing Sump Lines
For Entyce cases with a Sump Pump Configuration connect liquid line, suction line, electrical, and drain line to top case
stub-ups (outlets).
Note: Example below demonstrates the proper method of sealing refrigeration and electrical access points. En
sure tight seal to eliminate any air penetration.