background image

Rev. 0308

25

Limited Warranty

This warranty is made to the original user at the original installation site and is not transferable.

Hussmann merchandisers are warranted to be free from defect in material and workmanship under normal use

and service for a period of one (1) year from the date of original installation (not to exceed fifteen (15) months from the
date of shipment for the factory).  Hussmann Impact Modular Coils are warranted for a total of five (5) years
based upon the above criteria
.  Hussmann’s obligation under this warranty shall be limited to repairing or exchanging
any part or parts, without charge F.O.B. factory or nearest authorized parts depot within said period and which is proven
to the satisfaction of the original manufacturing plant warranty group to be thus defective.

Hussmann covers the entire case or refrigeration product and all its components (except for lamps, driers, fuses,

and other maintenance type replacement parts) for the one (1) year warranty period.

Additionally, Hussmann warrants for a total period of three (3) years all sealed, multi-glass assemblies except

those used in sliding doors on closed meat display cases.  If within three (3) years from the date of installation (not to
exceed thirty-nine (39) months from the date of shipment from factory), it shall be proven to the satisfaction of  the
originating factory warranty group that there is impaired visibility through the multi-glass assemblies thereof caused by
moisture between the glasses, the multi-glass assembly will be replaced free of charge, F.O.B. factory.  This additional
warranty excludes accident, misuse, or glass breakage.

On Hussmann manufactured self-contained display cases, Hussmann agrees to repair or exchange, at its option,

the original motor/compressor unit only with a motor/compressor of like or of similar design and capacity if it is shown
to the satisfaction of Hussmann that the motor/compressor is inoperative due to defects in factory workmanship or
material under normal use and service as outlined in Hussmann’s “Installation Instructions” which are shipped inside new
Hussmann equipment.  Hussmann’s sole obligation under this warranty shall be limited to a period not to exceed five
years from date of factory shipment.

On Hussmann refrigeration systems, an additional (4) year extended warranty for the motor/compressor

assembly is available, but must be purchased prior to shipment to be in effect.  Hussmann reserves the right to inspect
the job site, installation and reason for failure.

The motor/compressor warranties listed above do not include replacement or repair of controls, relays, capaci-

tors, overload protectors, valve plates, oil pumps, gaskets or any external part on the motor/compressor replaceable in
the field, or any other part of the refrigeration system or self-contained display case.

THE WARRANTIES TO REPAIR OR REPLACE ABOVE RECITED ARE THE ONLY WARRANTIES, EXPRESS,

IMPLIED OR STATUTORY, MADE BY HUSSMANN WITH RESPECT TO THE ABOVE MENTIONED EQUIPMENT,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND HUSSMANN NEITHER AS-
SUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT, ANY OTHER OBLIGATION OR LIABILITY IN CON-
NECTION WITH THE SALE OF SAID EQUIPMENT OR ANY PART THEREOF.

THIS WARRANTY SHALL NOT APPLY TO LOSS OF FOOD OR CONTENTS OF THE EQUIPMENT
DUE TO FAILURE FOR ANY REASON.  HUSSMANN SHALL NOT BE LIABLE
:

For payment of labor for any removal or installation of warranted parts;

For any repair or replacements made without the written consent of Hussmann, or when the equipment is installed or
operated in a manner contrary to the printed instructions covering installation and service which accompanied such
equipment;

For any damages, delays, or losses, direct or consequential which may arise in connection with such equipment or part
thereof;

For damages caused by fire, flood, strikes, acts of God or circumstances beyond its control;

When the equipment is subject to negligence, abuse, misuse or when the serial number of the equipment has been
removed, defaced, or altered;

When the equipment is operated on low or improper voltages

When the equipment is put to a use other than normally recommended by Hussmann (i.e. deli case used for fresh
meat);

When operation of this equipment is impaired due to improper drain installation;

For payment of refrigerant loss for any reason;

For costs related to shipping or handling of replacement parts.

Hussmann Corporation, Corporate Headquarters:  Bridgeton, Missouri, U.S.A. 63044

August 1, 1998

Summary of Contents for ASC-L

Page 1: ...ASCS L SERVICE GELATO AND ICE CREAM REV 0308 Installation Operation Manual ASC L ASCS L Lift up Curved Glass Refrigerated Service Gelato and Ice Cream Case p n IGSF ASC L ASCS L 0308 INSTALLATION OPE...

Page 2: ...Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier immediately and request an inspection Hussmann Chino will acknowledge shortages within ten days from re...

Page 3: ...nt position as possible Remove the top of the crate Detach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate skid Lift only a...

Page 4: ...gs over the highest part of the floor so that case is level Prevent damage case must be raised under leg or by use of 2x6 or 2x4 leg brace Remove side and back leg braces after case is set 3 Set secon...

Page 5: ...gerators or between a refrigerator and a wall provide means to prevent freezing The water seal should be insulated to prevent condensation Refrigeration GELATO SOFT ICE CREAM These display cases are d...

Page 6: ...Some supermarkets require a 4th sensor in the return air Case controllers will be located in the electrical race way or under the case THERMOSTATIC EXPANSION VALVE LOCATION This device is located on t...

Page 7: ...ay and duration up to 4 hours Four Relay Outputs Compressor defrost evaporator fan and alarm Adjustable Short Cycle Protection Extra protection for the equipment Non volatile memory The programmed par...

Page 8: ...mp down amount of time the compressor remains on after defrost initiates 0 to 59 min Drip time amount of time the compressor is locked out after defrost is terminated 0 to 59 min Defrost duration time...

Page 9: ...the upper right corner Fig 9 Sensor Connectors 3 Connecting the refrigeration defrost equipment Connect the wires from the compressor including the thermostat to the correspondent terminal on the bott...

Page 10: ...low these steps Step 1 SET Press and hold SET for 5 seconds The display will show CLoC Step 2 SET Press SET again to change the time of day Step 3 or Press UP or DOWN until the correct time of day is...

Page 11: ...nimum Compressor OnTime Con Minimum time that the compressor will remain turned on Range from 0 to 15 min Alarm Delay ALrd Time delay before the alarm goes off after the temperature fall off the two a...

Page 12: ...me Press UP or DOWN until the 11 59 PM appears on the display Press SET Press DOWN ten times to exit the programming level Error Codes Display Control Status Er 1 ERC Fault software or hardware failur...

Page 13: ...epower Rating hp 1 1 5 2 FLA LRA 16 96 12 72 12 72 Pilot Duty 470 470 470 DEFROST SPST NC 120VAC 208VAC 240VAC ResistiveAmps 16 16 16 Horsepower Rating hp 1 2 3 4 1 Pilot Duty VA 470 470 470 EVAPORATO...

Page 14: ...PERAGE Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may be less than specified Field wiring from the refrigeration control panel to the merchandisers...

Page 15: ...applicable Refrigeration performance will be seriously affected if left open for a prolonged period of time 8 Avoid the use of supplemental flood or spot lighting Display light intensity has been des...

Page 16: ...CARE Improper cleaning not only accelerates the cleaning cycle but also degrades the quality of this surface Normal daily buffing motions can generated static cling attracting dust to the surface Inc...

Page 17: ...de edge of the glass panel 3 Remove or re adjust the glass panel servicing always replace fan with a fan of the same specifi cations COPPER COILS The copper coils used in Hussmann merchandisers may be...

Page 18: ...800 5 10 5 120 5 Forced 41 2 4 16 1 0 72 1 04 3 05 15 0 3 13 Air Axial 208V ASC L ASCS L Ice Cream Electric Defrost Option 4 450 1 800 30 10 20 150 20 Forced 41 2 1 30 2 0 18 0 35 1 83 15 65 15 0 1 04...

Page 19: ...1 20 0 54 3 13 1 04 3 05 10 10 15 3 13 Ice Cream 450 5 400 30 10 20 150 20 Air Airsweep 41 2 Axial 3 208V ASC L ASCS L KOOL GAS Defrost Option 4 Frozen food 370 1 480 20 5 10 150 10 Forced Evap 8 x 10...

Page 20: ...VAC 50 60 Hz M M CANOPY LIGHTING 2 F25T8 SPX30 ANTI SWEAT HEATER 1 180W 115 VAC 125 01 3032 ANTI SWEAT FANS COMAIR ROTRON MX2B1 E1 2 0 18A 115 VAC 125 01 2012 A EVAPORATOR FANS EBM PAPST MODEL 9906L 0...

Page 21: ...LEDGE LIGHTS 2 FP28T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L CANOPY LIGHTS 4 F32T8 SPX30 NOSE LIGHTS 2 F32T8 SPX30 AiR SWEEP FANS 2 4 AXIAL MOTORS LIGHT SWITCH...

Page 22: ...of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to Hussmann s recommendations b Observation of ou...

Page 23: ...direct sunlight 9 Are display signs blocking or diverting air flow 10 Are the coils of the refrigerator iced up 11 Is the store ambient over 75 F 55 RH as set forth in ASHRAE Standard 72 and ASHRAE St...

Page 24: ...age equipment doors should be kept closed during periods of inactivity f Minimize the transfer time of perishables from storage to display g Keepmeatunderrefrigerationinmeatcuttingand processing area...

Page 25: ...er this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor a...

Page 26: ...particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by cont...