7. Remove honeycomb vents and wash in warm soapy water (All water must be removed from the honeycomb cells
before placing it back in the case). A vacuum cleaner may also be used to clean the honeycomb.
8. Wipe LED lamps with a dry cloth.
9. Carefully flush the waste drain and drain trap with a bucket of water and allow the base to drain.
10. Clean the waste drain/trap with a soft brush and warm water.
11. Wipe down the inside of the case, including the perforated air delivery panels and air return grill with a clean soft
cloth, warm water and mild detergent.
12. Clean glass or mirrored surfaces with a clean soft cloth and mild glass cleaner.
13. Clean the condenser unit with a soft brush or a vacuum cleaner. The dust and fluff obstructs the good air
circulation. To reach the condenser unit, remove the protection grill, clean it very carefully (avoid touching other
components) and put the grill back in its place.
14. Clean the dissipater tray - To reach the dissipater tray, remove the protection grill, slide out the tray, remove the
lid, clean (avoid touching other components) and replace in backward order ensuring the drain is over the lid
entry point of the tray
a. General clean with a sponge, warm water and mild detergent, then rinse and wipe dry.
b. Clean any rust, salt or deposits on and around the water level sensor assembly. There should not be any
deposits that cause conductance to the sensor and activate the heater.
15. Clean the outside of the case with warm water and a disinfectant solution.
16. Clean bumpers and other plastic parts with a soft cloth and mild detergent, then wipe dry with a clean cloth
17. Replace base trays and shelves and turn on case power
18. Reload stock after 30 minutes.
Yearly
It is recommended that the dissipater tray sensor tip assembly be replaced
Servicing
No servicing of Hussmann cases, including the replacement of LED lamps, is to be undertaken by store staff. Please
contact your service provider for all maintenance queries.