Installation manual
H1 Self Contained Multideck
_________________________________________________________________________________________________________________________
Page
5
Hussmann
Electrical Connection
– access from rear of case. Plug and lead is coiled up underneath the case, next to bottom
electrical box.
figure 3 rear view of case with electrical plug
Operating Environment
Cases have been factory tested to AS1731, 25
C at 60% RH. For a better performance and having operating
safety margin, store condition is recommended to be operating at or below 24
C
at 50% RH. Otherwise an “air
ventilation kit” may be required to avoid under or rear cabinet sweating
Air circulation gaps between the wall and the back of the case are shown in Figure 1 & 2, but reference should be made
to the PED for the latest, up to date information.
Cases must not be positioned in areas that may be subject to heat or air currents such as ventilation ducts, open doors or
windows, direct sunlight, electric fans or ovens, etc. Otherwise the cabinet may show poor temperature performance or
the operating life is affected. If fitted within a gondola run refer to appendix 2
NOTE
Refer to product MSDS for all hazardous
substances used during installation in
relation to their application, PPE, first aid,
disposal and emergency management.
Refer page 20 (Risk Analysis)
For MSDS sheet contact your Hussmann
Representative
Handling and Transporting cases
Case dimensions can be found in the product engineering data sheets.
(This manual is a guide only. Always refer to the latest case information available from Hussmann Customer Service)
Always ensure that the moving device is of a suitable type, and has sufficient lifting capacity for the case weight and
dimension. Always lift cases from the underside.
Refer to and follow the manual handling policies of your Company when moving cases.