background image

BEXD 

Data Sheet

4 of 5

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

BEXD

Medium Temperature

Electrical Data

Number of Fans 

8 ft

12 ft

Refrigeration – 4W

2

3

120V/60hz System

Export – 9W

230V 50 hz 

NA

NA

Amperes

Watts

Merchandiser

8 ft

12 ft

8ft

12 ft

Fans

Standard 0.58

0.87

48

72

Export:  230V 50 hz  

NA

NA

NA

NA

Nosing Anti-sweat Heaters (120V)

0.67

1.0

80

120

Minimum Circuit Ampacity

With Standard Fans 

0.6

0.9

With Export:  230V 50 hz Fans 

NA

NA

Maximum Over Circuit Protection 120V

20

20

Lighting

Standard 

None

Optional 

None

Summary of Contents for BEXD

Page 1: ...aporator 1 0392457 Standard Energy Efficient 0409511 Fan Blade B 0261933 Standard Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item HEATERS C 0401605 Nosing Anti sweat Heater 8 ft 3 0401606 Nosing Anti sweat Heater 12 ft Note Changed items have been underlined P N 0459615 BEXD Data Sheet Set P N 0459615 NSF Certified March 2004 ...

Page 2: ...pport and center support 44 5 8 1135 44 5 8 1135 Distance between edges of center supports NA 48 1 8 1222 Stub up area between front skid rail and splashguard 7 5 8 193 7 5 8 193 Electrical Service Electrical Field Wiring connection point Length of electrical raceway 32 3 4 831 32 3 4 831 B RH End of case to center of farthest knockout 90 1 4 2292 140 1 2 3569 Back of case to center of knockout 46...

Page 3: ...iguration and product loading OFFTIME Failsafe minutes 70 ELECTRIC OR GAS Not Available Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control BEXD CI CO Temp F 30 20 Indoor Unit Only Pressure Defrost Termination Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser BEXD Drip Pipe in 5 8 Liquid Line in 3 8 Suction Line in 7 8 E...

Page 4: ... 3 120V 60hz System Export 9W 230V 50 hz NA NA Amperes Watts Merchandiser 8 ft 12 ft 8ft 12 ft Fans Standard 0 58 0 87 48 72 Export 230V 50 hz NA NA NA NA Nosing Anti sweat Heaters 120V 0 67 1 0 80 120 Minimum Circuit Ampacity With Standard Fans 0 6 0 9 With Export 230V 50 hz Fans NA NA Maximum Over Circuit Protection 120V 20 20 Lighting Standard None Optional None ...

Page 5: ...ING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only BROWN BAND Fans BROWN BAND 120V POWER 120V NEUTRAL 1 120V POWER Anti Sweat Heaters Rear Rail 3 PURPLE BAND PURPLE BAND 120V NEUTRAL Fan Wiring Offtime Defrost 2 3 Fans ...