background image

5 of 10

P/N 0489565_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

C2XEC-E

Dairy/Delicatessen

Precut & Packaged Produce

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

600 (272)

800 (363)

1000 (454)

1200 (544)

75 (34)

5

Actual weights will vary according to optional kits included.

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

3.38 ft

3

/ft  (0.31 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

3.10 ft

/ft  (0.29 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

2.95 ft

2

/ft  (0.90 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

5.04 ft

2

/ft  (1.54 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (1) row of 12-inch shelf and 

(1) row of 14-inch shelf.

eparately from fans.

Summary of Contents for C2XEC-E

Page 1: ...n Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744...

Page 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Page 3: ...e a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C2XEC E 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant charge may...

Page 4: ...icient 0 39 0 44 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 6...

Page 5: ...9 m3 m ARI Total Display Area 3 Sq Ft Ft 2 95 ft2 ft 0 90 m2 m Shelf Area 4 Sq Ft Ft 5 04 ft2 ft 1 54 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m...

Page 6: ...o Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 6 5 6 6 Connector W B BL BL R BL R R R Optional Ligh...

Page 7: ...mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 6 5 6...

Page 8: ...L 8 8 R BL R BL R BL 8 8 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle dept...

Page 10: ...allast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...