REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
C2XEC-XE
Discharge Air °F
29
Evaporator °F
21
Unit Sizing °F
19
Btu/hr/ft — Unlit Shelves
C2XEC-XE
‡‡
Parallel
Conventional
U
NLIT
1080
1155
‡‡ Add 10 Btu/hr/ft
per shelf row
for LED fixtures.
Add 20 Btu/hr/ft
per shelf row
for fluorescent lamps.
DEFROST DATA
C2XEC-XE
Frequency (hr)
6
Defrost Water (lb/ft/day)
7
(±15% based on case configuration and
product loading.
O
FFTIME
C2XEC-XE
Temp Term °F
48°F
Failsafe Minutes
30
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
C2XEC-XE
CI/CO*
17
°
F / 7
°
F
Indoor Unit Only, Pressure Defrost
Termination*
48
°
F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)**
C2XEC-XE
4 ft
1.2
6 ft
1.6
8 ft
2.3
12 ft
3.3
**This is an average for all refrigerant types. Actual
refrigerant charge may vary by approximately half a
pound.
Dimensions shown as inches and (mm).
P/N 0489566_B
3 of 10
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
55
3
/
4
(1415)
31
5
/
8
(804)
4
3
/
4
(120)
30
1
/
4
(768)
42
(1064)
33
1
/
2
(851)
26
1
/
4
(665)
C2XEC-XE
30
1
/
4
(768)
22
(559)
FAN
C
O
I
L
3 In.
(77 mm)
Required
Air Gap
4
7
/
8
(123)
Electrical
Case to Case
Connections
17
1
/
8
(436)
33
1
/
8
(841)
31
1
/
4
(793)
21
1
/
4
(540)
23
5
/
8
(600)
3
5
/
8
(92)
Impact
Excel
C2XEC-XE
Dairy/Delicatessen
Precut & Packaged Produce
Multi-deck, 4 Display Levels, 55 In. Back
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.
See Page 9 for
shelf arrangement.