background image

8 of 10

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C2XEC-XE

Technical Data Sheet

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

8

8

8

8

8

8

8

R

BL

7

B

B

W

W

BL

R

G

4 ft case

6 ft or 8 ft case

12 ft case

(TYP)

Shelf Light

Plug & Receptacle

B

Connector

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

8

8

8

8

8

8

8

R

BL

7

B

B

W

W

BL

R

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

8

8

8

8

8

8

8

R

BL

7

B

B

W

W

BL

R

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

W

Connector

Optional Shelf Harness and LED Light Circuits for 
 
 
3, 4, 5, 6 & 7 Rows of Shelves

Optional Shelf Lighting
LED Fixtures

Summary of Contents for C2XEC-XE

Page 1: ...n Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744...

Page 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Page 3: ...n 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C2XEC XE 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant...

Page 4: ...Efficient 0 39 0 44 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V...

Page 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 29 ft2 ft 1 00 m2 m Shelf Area 4 Sq Ft Ft 6 54 ft2 ft 1 99 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m...

Page 6: ...wo Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 6 5 6 6 Connector W B BL BL R BL R R R Optional Lig...

Page 7: ...echanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 6 6 6 B W 6 ft...

Page 8: ...L R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Page 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth...

Page 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...

Reviews: